What this opportunity is
The Department of Defense is seeking a contractor to provide a Computed Tomography (CT) system for the Fleet Readiness Center Southwest in California. This requirement is for the installation of a turn-key system to support the inspection of flight components and additive manufacturing parts. There is no set-aside for small businesses, and the notice type is Sources Sought, indicating that interested vendors should track this opportunity for potential future solicitations rather than submit bids at this stage.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
SCOPE: Fleet Readiness Center Southwest (FRCSW) requires a Computed Tomography (CT) system. This new capability is necessary to support the inspection of flight components and future additive manufacturing (AM) fabricated aircraft parts and components at the FRCSW maintenance facility on board Naval Air Station (NAS) North Island in California. The contractor shall be responsible for the complete installation of all new equipment, training personnel, rigging, quality assurance, and necessary equipment to provide a turn-key system in shop KF75820, building 250 located at FRCSW North Island, CA.
APPLICABLE DOCUMENTS: The documents listed in this section are cited in Sections 3.0, 4.0 and 5.0 of this specification. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all requirements of documents cited in Sections 3.0, 4.0, and 5.0, whether or not they are listed in Section 2. Unless otherwise specified, the documents listed in the solicitation or contract shall be the current edition at time of solicitation.
Government Documents.
Specifications, Standards, and Instructions. The following specifications, standards and instructions from a part of this document to the extent specified herein.
Code of Federal Regulations (CFR)
21 CFR 1020.40: Performance Standards for Ionizing Radiation Emitting Products: Cabinet X-Ray Systems
29 CFR 1910.1096: Ionizing Radiation Safety Enablement
29 CFR 1910.147: Control of Hazardous Energy (Lockout/Tagout)
29 CFR Subpart S: Electrical Safety-Related Work Practices
29 CFR 1910.212: General Requirements for all machines
29 CFR 1910.1200: Hazardous Material Communication
Department of Defense Instructions (DODI)
DODI 8500.2; Information Assurance (IA) Implementation
DODI 6055.08; Occupational Ionizing Radiation Protection Program
(Applications for copies should be requested at www.esd.whs.mil/DD/DoD-Issuances/)
Other Government Documents, Drawing, and Publications The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the documents listed in the solicitation or contract shall be the current edition at time of solicitation.
LOCAL DOCUMENTS
FRCSWINST 5104.2L w-CH-1 IONIZING RADIATION SAFETY PROGRAM (Distribution A)
Layout Drawing
Building 250 CT X-Ray Cabinet System Area Layout (Distribution A)
Non-Government Publications, Specifications, Standards, and Handbooks.
American Society for Testing and Materials (ASTM)
ASTM E2597/E2597M - 22 Standard Practice for Manufacturing Characterization of Digital Detector Array
ASTM E2737-23 Standard Practice for Digital Detector Array Performance Evaluation and Long-Term Stability
ASTM E2339-20 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)
(Applications for copies should be addressed to ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428.)
National Fire Protection Association (NFPA)
NFPA 70, National Electrical Code
(Applications for copies should be addressed to the National Fire Protection Association, ATTN: Support Services, 11 Tracy Drive, Avon, MA 02322)
American Society of Mechanical Engineers (ASME)
ASME Y14.5-2018 Dimensioning and Tolerancing
ASME Y14.100 Engineering Drawing Practices
(Applications for copies should be addressed to ASME International Three Park Avenue, New York, NY 10016-5990 or www.asme.org)
International Organization for Standardization
ISO 10303, Industrial automation systems and integration — Product data representation and exchange.
Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained
REQUIREMENTS: The contractor shall provide and install a complete CT system in the designated space as shown in the Layout Drawing. It is the responsibility of the contractor to get the entire unit or assembled components to the prescribed space and meet all requirements as set below as a complete system.
System Capabilities: System shall meet all functions described below:
Advanced 2-Dimensional X-Ray inspection
2-Dimensional CT slice visualization
CT volume reconstruction for 3-Dimensional inspection
3-Dimensional internal and external surface inspection and visualization
Measurement, visualization, and analysis tools
X-Ray tube types and configuration shall be a dual-tube configuration consisting of a 225 kV micro-focus & 450kV mini-focus tube.
The system shall have a voltage range of 20 kV – 450kV.
Single-pass acquisition method for elongated objects: The system shall perform automated acquisition for elongated objects that typically do not fit in a single exposure without requiring volume stitching. The object length is only limited by the systems scanning area. This method reduces or eliminates the cone angle artifacts caused by flat, planar features common in non-spiral CT techniques. This method must support continuous scan operation.
Method for expanding imagining field beyond detector panel size to cabinet size: The system shall fully scan a part that is larger than the detector panel. The system shall perform scanning in step and continuous modes while moving the detector to a series of locations to increase the scanned volume without changing the system geometry.
Method of achieving resolution beyond detector panel resolution: The designed motion of the manipulator and the software shall display and analyze scan data utilizing sub-pixel analysis routines. Resolution shall be at least triple the detector’s native resolution. This method must support continuous scan operation.…
Source: SAM.gov, as posted. Verify the current solicitation before responding.