Description
STATEMENT OF WORK
FALL ARREST SYSTEM INSPECTION
Fairchild Air Force Base, Washington
DESCRIPTION OF WORK. Contractor shall perform annual inspections of the fall protection
systems located in building 2050 hangars No. 1, 2, 3, & 4 located at Fairchild AFB, Washington.
Building 2050 is located in a controlled area. Escorts will be provided by the government as
coordinated in advance to perform services. Non-U.S. citizen workers are prohibited from accessing
the controlled area. The annual inspection shall be performed in accordance with all federal, state,
local regulations and manufacturer recommendations. The inspection is necessary to ensure continued
compliance with OSHA Regulations and manufacturer recommendations. The contractor shall
provide an 85-foot lift to access the system.
As a minimum the inspection shall consist of the following actions:
A hands on inspection of all components of the installed system
Visually verify all end terminations
Tighten all lock nuts to the required torque
Inspect for presence of cotter pins where appropriate
Check for damage to all components including cable along its entire length, intermediate brackets
and end termination
Inspect intermediate brackets for excessive deformation
Perform minor repairs as needed
Photo document any in-depth repairs that may be required
Inspect user equipment supplied with the original system or replacement of same make and
model, including harnesses and lanyards.
Perform all other actions required to comply with OSHA and/or manufacturer’s inspection
requirements.
The inspection will be limited to the engineered system components installed by Evan Corporation or
manufactured by Capital Safety Group and installed by others.
At the completion of the inspection, the contractor shall issue a written report attesting to the condition of
the system and its conformance with OSHA Regulations. The report shall include an estimate for any
repairs that may be required.
OPERATIONS SECURITY (OPSEC) REQUIREMENTS. The contractor will protect critical and/or
sensitive information from disclosure. The DoD contractor will:
1. Be familiar with their organization’s critical information. When publicly posting or publishing work-
related information that potentially contains critical or sensitive information airmen are encouraged to
solicit the advice of their immediate supervisor, security office and/or OPSEC Program
Manager/Coordinator.
2. Consider attempts by unauthorized personnel to solicit critical and/or sensitive information as human
intelligence (HUMINT) gathering and consider it a HUMINT incident. Contract personnel who have
been involved in or have knowledge of a possible incident will report all facts immediately to the nearest
supporting Air Force Office of Special Investigations (AFOSI) office.
3. If AFOSI is not readily available, HUMINT incidents will be reported to the organization’s security
manager or commander who will ensure that, without exception, reports are relayed as securely and
expeditiously within 24 hours to the nearest AFOSI organization.
FA462020P0063
Attachment 1
Page 1 of 2
-- 1 of 18 --
HOURS OF OPERATION. The normal hours of operation are 0800-1700, Monday-Friday excluding
federal holidays. The following federal holidays are observed:
January 1 New Years Day
3 rd Monday in January Martin Luther King, Jr. Day
3 rd Monday in February President’s Day
Last Monday in May Memorial Day
July 4 Independence Day
1 st Monday in September Labor Day
2 nd Monday in October Columbus Day
November 11 Veterans Day
4 th Thursday in November Thanksgiving Day
December 25 Christmas
ATTACHMENTS:
1. Inspection Criteria
FA462020P0063
Attachment 1
Page 2 of 2
-- 2 of 18 --
-- 3 of 18 --
-- 4 of 18 --
-- 5 of 18 --
-- 6 of 18 --
-- 7 of 18 --
-- 8 of 18 --
-- 9 of 18 --
-- 10 of 18 --
-- 11 of 18 --
-- 12 of 18 --
-- 13 of 18 --
-- 14 of 18 --
Inspection, Care & Maintenance
Horizontal Lifelines
Frequency:
Visually inspect anchors and
connectors before each use
in accordance with
manufacturer's instructions.
Damaged systems and
components must be
removed from service
immediately.
In the event of a fall, the system must be removed from
service, inspected, repaired and recertified for use by Evan
Corporation.
Inspect system components for:
• Excessive corrosion, dents, cracks, fraying and
deformities.
• Check end anchor fasteners and intermediate brackets
(end anchors must be torqued at 75 ft.lbs. and
intermediate brackets at 18 ft.lbs.).
• Check site label(s) making sure they are present,
legible, and secured near an access location.
• Inspect User Equipment per associated manufacturer's
instructions. Check connecting means for wear or
deformities.
17
FA462020P0063
SOW Attachment 1
Page 10 of 13
-- 15 of 18 --
FA462020P0063
SOW Attachment 1
Page 11 of 13
-- 16 of 18 --
Inspection, Care & Maintenance
Rigid Rail - Enclosed Track and Wide Flange
Beams
• Check site label(s) making sure they are present,
legible, and secured near an access location.
• Inspect system prior to each use as per ANSI.
• Inspect User Equipment per associated manufacturer's
instructions.
• Refer to the instructions supplied with the harness,
lanyard and self-retracting lifeline for cleaning and
servicing pro cedures. Store the harness, lanyard or
self-retracting lifeline in a cool, dry clean environment
and out of direct sunlight.
• In the event of a fall, the system must be removed from
service until it is inspected and approved for us.e.
FA462020P0063
SOW Attachment 1
Page 12 of 13
-- 17 of 18 --
FA462020P0063
SOW Attachment 1
Page 13 of 13
-- 18 of 18 --