Skip to content

Open for responses

Full-service maintenance, inspection, calibration, and repair of a body plethysmograph system

HEALTH AND HUMAN SERVICES, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
RFQ24627Q0002
NAICS
811210
PSC
J065
Set-aside
Small Business Set Aside - Total
Posted
November 23, 2026
Response due
November 25, 2026
Place of performance
Lawton, OK

What this opportunity is

The Department of Health and Human Services is seeking a contractor for full-service maintenance, inspection, calibration, and repair of a body plethysmograph system at the Lawton Indian Hospital in Oklahoma. This opportunity is set aside for small businesses, making it suitable for firms specializing in medical equipment maintenance under NAICS 811210. Interested vendors should note that this is a Combined Synopsis/Solicitation, indicating they should track the notice for potential bidding opportunities rather than submitting a proposal at this stage.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Department of Health and Human Services Indian Health Service Performance Work Statement (PWS) Lawton Service Unit – Respiratory Therapy MGC Diagnostic Platinum RTD Elite Series Service Contract 11/03/2026 1. PURPOSE / BACKGROUND The Indian Health Service (IHS), an operating division within the U.S. Department of Health and Human Services (HHS), is responsible for providing federal health services to American Indians and Alaska Natives. The mission of IHS is to raise the physical, mental, social, and spiritual health of American Indians and Alaska Natives to the highest level and to assure that comprehensive, culturally acceptable personal and public health services are available and accessible to members of the 574 federally recognized Tribes across the United States. The Lawton Service Unit (LSU) is a Joint Commission–accredited federal healthcare facility in Oklahoma. The mission of the Lawton Service Unit is to deliver quality care in order to attain positive health outcomes for all valued patients with emphasis on cultural sensitivity and human dignity. To support this mission, the Respiratory Therapy Department utilizes specialized pulmonary diagnostic equipment to assess and treat cardiopulmonary conditions. The purpose of this Performance Work Statement (PWS) is to establish a full-service maintenance, inspection, calibration, and repair agreement for the Respiratory Therapy Department’s MGC Diagnostics Platinum Elite DL Series w/ Body Plethysmograph system located at the USPHS Lawton Indian Hospital. This PWS defines the required outcomes; except where specific technical or manufacturer standards are mandated, the methods used to achieve those outcomes are the responsibility of the Contractor. 2. SCOPE / REQUIRED OUTCOMES The Contractor shall provide all necessary labor, certified technicians, original equipment manufacturer (OEM) replacement parts, calibration standards, testing equipment, travel, and shipping necessary to maintain the MGC Diagnostics Platinum RTD Elite Series with Body Plethysmograph system in optimal, certified operating condition. All preventative maintenance, calibrations, diagnostic tests, and system recertifications shall strictly adhere to Medical Graphics Corporation (MGC) manufacturer specifications, applicable Federal regulations, and The Joint Commission accreditation standards. Location of Service: USPHS Lawton Indian Hospital Respiratory Therapy Department 1515 Lawrie Tatum Road Lawton, Oklahoma 73507 -- 1 of 11 -- Department of Health and Human Services Indian Health Service 3. PERFORMANCE REQUIREMENTS AND STANDARDS The Contractor’s performance will be evaluated against the following standards. (See Section 10 for the Quality Assurance / Surveillance Matrix.) # Required Service (Outcome) Performance Standard Acceptable Quality Level (AQL) Method of Surveillance 3.1 Annual Scheduled Preventative Maintenance (PM) & Recertification Complete annual factory-level PM, comprehensive multi- point inspection, calibration, and full system recertification per MGC specifications. Performed within ±30 calendar days of the scheduled annual anniversary date; 100% compliant with OEM criteria. Detailed Field Service Report & Biomedical verification. 3.2 Unscheduled Emergency & Corrective Repairs On-site response and diagnostic correction for unexpected system malfunctions or hardware failures using OEM components. On-site technician arrival within 24 to 48 hours from initial LSU service call; system restored to operational readiness. LSU Bio-Med service ticket logs & Contractor work orders. -- 2 of 11 -- Department of Health and Human Services Indian Health Service # Required Service (Outcome) Performance Standard Acceptable Quality Level (AQL) Method of Surveillance 3.3 Replacement Parts & Hardware Warranty All replacement components, circuit boards, and sensors must be new OEM parts manufactured or authorized by Medical Graphics Corporation (MGC). 100% OEM parts; minimum 1-year (12-month) warranty on all installed parts and associated labor. Work order itemization, parts receipts, and invoice review. 3.4 Technical Phone & Remote Diagnostics Support Direct access to certified technical specialists for real- time troubleshooting, system error resolution, and operational guidance. Priority toll-free phone and remote assistance available 6:00 AM – 8:00 PM CST, Monday through Friday (excluding federal holidays). Call response ” 1 hour. LSU staff trouble logs and vendor teleconference records. 3.5 Service Documentation & Joint Commission Compliance Comprehensive, itemized Field Service Reports detailing inspection items, as- found/as-left test results, calibrations, replaced parts, and system clearance. 100% of reports submitted to LSU Biomedical Engineering and Respiratory Therapy within 10 calendar days of service completion. Document review against Joint Commission standards. -- 3 of 11 -- Department of Health and Human Services Indian Health Service 4. CONTRACTOR RESPONSIBILITIES 4.1. Preventative Maintenance and Recertification The Contractor shall perform one (1) comprehensive annual Preventative Maintenance inspection and system recertification visit per contract year, scheduled within 30 days prior to or 30 days after the annual service date. PM procedures must conform to Medical Graphics Corporation (MGC) guidelines and include, at a minimum: Comprehensive physical and mechanical inspection of the body plethysmograph cabin, door seals, latching mechanisms, and structural components. Electronic calibration of pressure transducers, pneumotachographs, flow sensors, gas analyzers, and automated valve circuits. System leak checks, baseline electronic alignment, and verification of software diagnostic routines. Affixing a visible, legible inspection sticker indicating date inspected, next due date, technician signature, and pass/fail certification. # Required Service (Outcome) Performance Standard Acceptable Quality Level (AQL) Method of Surveillance 3.6 Tech…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 811210