NB688000-26-01820 Two-Channel Microwave Signal Generator

COMMERCE, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
NB688000-26-01820_Two-Channel_Microwave_Signal_Generator
NAICS
334516
PSC
6640
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 13, 2026
Response due
July 27, 2026
Place of performance
Boulder, CO

Description

R Requirements / Specifications: Two-channel microwave signal generator 1 Version 1.0 (2019) Double-click on  for further assistance. Use this document to detail specifications/requirements for an item and/or ancillary services.  TITLE: Two-channel microwave signal generator  Requesting Lab/Division/Group: PML/Time and Frequency/Precision Photonic Synthesis Group General Statement of Need  To support our research activities developing ultrastable lasers and low noise microwave signals, we require a two-channel microwave signal generator with output frequencies up to 12 GHz for signal characterization and analysis. Items and/or Ancillary Services  Item 1: Two-channel microwave signal generator Quantity: 1 Specifications: 1.1 Number of output channels: 2 1.2 Channel to channel isolation: > 75 dB at 0 dBm output 1.3 Ouput frequency range on each channel: at least 1 MHz to 12 GHz 1.4 Output waveforms: continuous-wave; modulated continuous-wave 1.5 Capable of both internal and external modulation of amplitude, frequency or phase over full carrier frequency range 1.6 External referencing: can accept external 10 MHz timebase 1.7 Phase noise, 10 kHz offset: < - 125 dBc/Hz on a 1 GHz carrier; < -105 dBc/Hz on a 10 GHz carrier. 1.8 Output impedance: 50 ohm 1.9 Output connector: N-type or sma or 3.5 mm 1.10 Minimum frequency step size: 0.05 Hz or less 1.11 Output power range: at least -30 dBm to + 10 dBm for an output frequency ranging from 10 MHz to 12 GHz 1.12 Output power setting resolution: at least 0.05 dB 1.13 Channel-to-channel phase stability: better than 2 deg. on a 10 GHz carrier 1.14 Phase setting range: +/- 180 deg. 1.15 Phase setting resolution: at least 0.1 deg. 1.16 Communication interface: USB or GPIB 1.17 Device operation: may be self-contained within the unit, externally computer controlled, or both 1.18 Setting display: current settings may be displayed on the unit, on an external monitor or computer, or all of these Separately Priced Options and Services: Item 2: [List minimum specifications. Quantity: [Enter quantity here.] Specifications: [Enter quantity here.] [List any other item(s) or service requirements here using the same format above.] -- 1 of 4 -- R Requirements / Specifications: Two-channel microwave signal generator 2 Version 1.0 (2019) Double-click on  for further assistance. Service Requirements / Item Specifications Section  Requirements/Specifications  Planning Considerations ☒ N/A ☐ List any visits required to allow potential vendors to see site specific constraints. [Explain requirement here] ☐ US citizen required on-site (foreign nationals require preregistration 30 days prior) ☐ Vendor rep on-site more than three days ☐ Other considerations: [List other considerations to ensure an accurate quote] Shipping & Delivery ☐ N/A [Enter shipping and delivery information by item here.] Shipping criteria: ☐ Partial delivery acceptable ☐ Direct delivery to building required [Explain need for requirement here] Building has: ☐ Loading dock ☐ Containerization preference: [Choose container] Other requirements: [List any other requirements here] Delivery date criteria: ☒ Delivery of goods, installation, and training shall be completed no later than: 12 weeks ARO ☐ Deliver no earlier than: [Insert date here] ☐ Other: [List other shipping, delivery, or specil requirements] Electronic Media ☒ N/A [Enter electronic media requirements by item here.] ☐ Software ☐ Electronic manuals ☐ License Key ☐ Other: [List any other Electronic Media requirements here] [Enter email address for software delivery here] Installation ☒ N/A [Enter installation requirements by item here.] ☐ Vendor technician on site ☐ Rigging ☐ Uncrating / Unpackaging ☐ Removal of packaging material ☐ Equipment set up ☐ Start-up services ☐ Turn key installation ☐ Other [Enter details here.] Note: When installation is required, TPOC or COR shall be the coordination point. Facility / Utility Considerations ☒ N/A [List site specific utility considerations by item here.] ☐ OFPM Work Order Number(s) [List any Work Order Number(s) here] ☐ Power available Voltage: [Enter voltage here] (V) Max Current: [Enter max current draw here] (A) -- 2 of 4 -- R Requirements / Specifications: Two-channel microwave signal generator 3 Version 1.0 (2019) Double-click on  for further assistance. Phase: [Choose phase] Frequency: [Typically 60Hz] (Hz) NEMA Plug Type: [Enter plug type here] (i.e.: NEMA L5-20P) Environment: [Choose environment] Other power consideration: [List any other power considerations here] ☐ Utility connections: [L ist relevant available utilities, pressure(s), and flowrate(s)] ☐ Other considerations: [List other considerations to ensure an accurate quote] Warranty  ☐ N/A Base Manufacturer Warranty is acceptable [If you require an Extended Manufacturer Warranty, describe the warranty requirements per item here.] What is included? ☐ Labor ☐ Parts ☐ Travel ☐ Cost and liability for returns ☐ Other: [Enter other requirements here] ☐ Warranty length: [Enter warranty length here] Period Length:[Ex. month, 6 month, year etc.] Training ☒ N/A [Training requirements (who, when, what, where) here. If on-site, is travel necessary?] ☐ On-site ☐ Off-site location: [Enter location(s) here] ☐ Number of trainees: [Enter number of trainees here] Scope of training: ☐ Operations ☐ Maintenance ☐ Troubleshooting ☐ Safety ☐ Other: [Enter other scope requirements here] ☐ Training materials to be provided: [Describe requirement here] ☐ Other: [Enter other training requirements here] Note: When training is required, TPOC or COR shall be the coordination point. Inspection and Acceptance ☐ N/A [Enter inspection requirements per item here] ☒ Planned government acceptance testing (7 business days) ☐ Gov’t acceptance expected to take longer than 7 business days: [Duration] ☐ Inspection and acceptance plan: [Explain here] ☐ Other: [Enter other requirements here] Maintenance ☒ N/A [Describe your maintenance requirements per i

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 334516)