Skip to content

Open for responses

NMUSAF DAF Heritage Program Maintenance, Fabrication, and Support Equipment

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
AFLCMC_NMUSAF
NAICS
333998
PSC
7910
Posted
November 16, 2026
Response due
November 19, 2026
Place of performance
Wright Patterson AFB, OH

What this opportunity is

The Department of Defense is conducting a sources sought notice to identify small businesses capable of providing five specific commercial equipment items for the National Museum of the United States Air Force at Wright-Patterson Air Force Base, Ohio. The required items include an electronic powered rough terrain scissors lift, two types of ride-on floor scrubbers/sweepers, a mobile welding table, and a tool storage center. This opportunity is suitable for various small business types, including 8(a), HUBZone, EDWOSB, WOSB, SDB, and SDVOSB. Interested firms should note that this is a market research effort, not a request for proposals, and responses must demonstrate technical compliance with the specified requirements.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

STATEMENT OF WORK DAF Heritage Program Maintenance, Fabrication, and Support Equipment 28 October 2026 1. BACKGROUND This equipment directly supports Government curatorial, restoration, and preservation specialists in fulfilling statutory stewardship, conservation, and public display responsibilities for more than 3,500 historical aerospace vehicles, ballistic missiles, and drones. Government personnel carry out these preservation activities in accordance with DAFI 84-103, Department of the Air Force Heritage Program. 2. SCOPE The Contractor shall furnish and deliver five (5) commercial equipment items to the National Museum of the United States Air Force (NMUSAF) located at Wright-Patterson Air Force Base (WPAFB), Ohio. The required equipment includes: one (1) Electronic Powered Rough Terrain Scissors Lift, one (1) Large Ride-on Floor Scrubber/Sweeper, one (1) Small Ride-on Floor Scrubber/sweeper, one (1) Mobile Welding Table, and one (1) Tool Storage Center. 3. TECHNICAL REQUIREMENTS All equipment furnished under this contract shall be new (not used, re-conditioned, refurbished, or prototype) and standard commercial production models. 3.1. Electric-Powered Rough Terrain Mobile Scissor Lift The Contractor shall provide an electric-powered, rough-terrain, self-propelled mobile scissor lift meeting the following minimum salient characteristics: 3.1.1. Lift Height, Reach, and Weight Capacity 3.1.1.1. Platform Working Height: Elevated platform height shall reach a minimum of 40 feet above ground level to permit technicians safe, direct overhead access to elevated suspended aircraft structural points. 3.1.1.2. Stowed Travel Height: Maximum stowed platform height shall not exceed 5 feet to maintain a low center of gravity during transit beneath low- hanging airframes. 3.1.1.3. Platform Load Capacity: Main platform weight capacity shall be 800 lbs minimum. The platform extension slide-out deck shall have a minimum load capacity of 300 lbs and provide at least 40 inches of horizontal extension to reach over wing roots without vehicle repositioning. 3.1.1.4. Elevation Speed: Full vertical lift and descent cycling time shall not exceed 60 seconds. 3.1.2. Dimensions and Adjustability: -- 1 of 10 -- 3.1.2.1. Dimensional Clearances: Overall vehicle width shall be between 50 inches minimum and 70 inches maximum (Shall Not Exceed 70”) to navigate standard museum hangar roll-up doors. Overall stowed length shall not exceed 132 inches. 3.1.2.2. Drive Control & Elevated Transit: Equipment shall feature proportional, variable-speed electric drive controls capable of driving at full elevated platform height across flat, level surfaces. 3.1.2.3. Transit Performance: Travel speed shall be a minimum of 3.0 mph when stowed. Gradeability shall be a minimum of 30% to negotiate outdoor connecting ramps between exhibition hangars. 3.1.2.4. Ground Clearance & Tilt Tolerance: Minimum ground clearance shall be 9.0 inches. Vehicle shall include an electronic slope/tilt sensor with operational interlocks permitting side-to-side tilt up to 2.0 degrees and fore- to-aft tilt up to 2.5 degrees prior to motion cut-out. 3.1.3. Safety and Protection: 3.1.3.1. Airframe & Floor Protection: All wheels shall be equipped with foam- filled, non-marking commercial industrial tires to eliminate scuffing or tracking on high-gloss museum gallery floor coatings and prevent flat-tire tipping hazards. 3.1.3.2. Fall Protection: Platform shall feature a complete tubular steel perimeter guardrail system with toe-boards, self-closing safety gate, designated lanyard anchor points, and a fold-down railing mechanism to reduce overall clearance height during transit between low-clearance hangar doorways. 3.1.3.3. Emergency Descent: Platform and base shall include an accessible manual emergency descent cable/release system to safely lower personnel in the event of primary power failure. 3.1.3.4. Transport Security & Metering: Chassis shall feature dedicated tie- down lugs for flatbed transport and a digital run-time hour meter for maintenance scheduling. 3.1.4. Power & Electrical: 3.1.4.1. Drive Power: Industrial heavy-duty electric battery bank providing sufficient capacity for a full 8-hour museum work shift under normal cycling. 3.1.4.2. Charging & Utilities: System shall include an integrated onboard smart battery charger compatible with standard 120V AC facility power. Platform shall include a factory-installed, weather-protected 110V AC GFCI electrical receptacle wired through the scissor stack to power handheld restoration tools. 3.2. Large Ride-On Industrial Floor Scrubber / Sweeper The Contractor shall provide a heavy-duty, ride-on industrial combination floor scrubber/sweeper meeting the following minimum salient characteristics: -- 2 of 10 -- 3.2.1 Cleaning Productivity & Operating Performance: 3.2.1.1 Cleaning Capacity: Theoretical cleaning productivity shall be a minimum of 115,000 square feet per hour to support continuous cleaning across wide-span exhibition hangars. 3.2.1.2 Scrub Path: Scrubbing deck cleaning path width shall be a minimum of 48 inches. Scrub deck shall utilize dual or triple commercial disk scrub heads. 3.2.1.3 Scrub Down Pressure: System shall feature variable scrub brush down pressure capable of delivering up to 350 lbs of down pressure to remove heavy rubber tire marks, fluid residues, and legacy hangar contaminants. 3.2.1.4 Drive Speed: Variable-speed drive system operating from 0 to 5.5 mph with operator cruise control. 3.2.1.5 Operational Run Time: Deep-cycle industrial battery pack providing a verified continuous operating run-time of not less than 5.0 hours under active scrubbing load. 3.2.2 Debris Sweeping, Dust Cleanup & Water Handling: 3.2.2.1 Wet/Dry Debris Collection: Integrated forward sweeper module with a solid debris collection hopper capacity of at least 6.0 cubic feet (𝑓𝑓𝑡𝑡 3) to collect Foreign Object Debris (FOD) prior to wet scrubbing. 3.2.2.2 High-Dump H…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 333998