The Department of Defense is conducting a sources sought notice to identify small businesses capable of providing five specific commercial equipment items for the National Museum of the United States Air Force at Wright-Patterson Air Force Base, Ohio. The required items include an electronic powered rough terrain scissors lift, two types of ride-on floor scrubbers/sweepers, a mobile welding table, and a tool storage center. This opportunity is suitable for various small business types, including 8(a), HUBZone, EDWOSB, WOSB, SDB, and SDVOSB. Interested firms should note that this is a market research effort, not a request for proposals, and responses must demonstrate technical compliance with the specified requirements.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
STATEMENT OF WORK
DAF Heritage Program Maintenance, Fabrication, and Support Equipment
28 October 2026
1. BACKGROUND
This equipment directly supports Government curatorial, restoration, and preservation
specialists in fulfilling statutory stewardship, conservation, and public display
responsibilities for more than 3,500 historical aerospace vehicles, ballistic missiles, and
drones. Government personnel carry out these preservation activities in accordance with
DAFI 84-103, Department of the Air Force Heritage Program.
2. SCOPE
The Contractor shall furnish and deliver five (5) commercial equipment items to the National
Museum of the United States Air Force (NMUSAF) located at Wright-Patterson Air Force
Base (WPAFB), Ohio. The required equipment includes: one (1) Electronic Powered Rough
Terrain Scissors Lift, one (1) Large Ride-on Floor Scrubber/Sweeper, one (1) Small Ride-on
Floor Scrubber/sweeper, one (1) Mobile Welding Table, and one (1) Tool Storage Center.
3. TECHNICAL REQUIREMENTS
All equipment furnished under this contract shall be new (not used, re-conditioned,
refurbished, or prototype) and standard commercial production models.
3.1. Electric-Powered Rough Terrain Mobile Scissor Lift
The Contractor shall provide an electric-powered, rough-terrain, self-propelled mobile
scissor lift meeting the following minimum salient characteristics:
3.1.1. Lift Height, Reach, and Weight Capacity
3.1.1.1. Platform Working Height: Elevated platform height shall reach a
minimum of 40 feet above ground level to permit technicians safe, direct
overhead access to elevated suspended aircraft structural points.
3.1.1.2. Stowed Travel Height: Maximum stowed platform height shall not
exceed 5 feet to maintain a low center of gravity during transit beneath low-
hanging airframes.
3.1.1.3. Platform Load Capacity: Main platform weight capacity shall be 800 lbs
minimum. The platform extension slide-out deck shall have a minimum load
capacity of 300 lbs and provide at least 40 inches of horizontal extension to
reach over wing roots without vehicle repositioning.
3.1.1.4. Elevation Speed: Full vertical lift and descent cycling time shall not
exceed 60 seconds.
3.1.2. Dimensions and Adjustability:
-- 1 of 10 --
3.1.2.1. Dimensional Clearances: Overall vehicle width shall be between 50
inches minimum and 70 inches maximum (Shall Not Exceed 70”) to navigate
standard museum hangar roll-up doors. Overall stowed length shall not
exceed 132 inches.
3.1.2.2. Drive Control & Elevated Transit: Equipment shall feature
proportional, variable-speed electric drive controls capable of driving at full
elevated platform height across flat, level surfaces.
3.1.2.3. Transit Performance: Travel speed shall be a minimum of 3.0 mph when
stowed. Gradeability shall be a minimum of 30% to negotiate outdoor
connecting ramps between exhibition hangars.
3.1.2.4. Ground Clearance & Tilt Tolerance: Minimum ground clearance shall
be 9.0 inches. Vehicle shall include an electronic slope/tilt sensor with
operational interlocks permitting side-to-side tilt up to 2.0 degrees and fore-
to-aft tilt up to 2.5 degrees prior to motion cut-out.
3.1.3. Safety and Protection:
3.1.3.1. Airframe & Floor Protection: All wheels shall be equipped with foam-
filled, non-marking commercial industrial tires to eliminate scuffing or
tracking on high-gloss museum gallery floor coatings and prevent flat-tire
tipping hazards.
3.1.3.2. Fall Protection: Platform shall feature a complete tubular steel perimeter
guardrail system with toe-boards, self-closing safety gate, designated lanyard
anchor points, and a fold-down railing mechanism to reduce overall clearance
height during transit between low-clearance hangar doorways.
3.1.3.3. Emergency Descent: Platform and base shall include an accessible
manual emergency descent cable/release system to safely lower personnel in
the event of primary power failure.
3.1.3.4. Transport Security & Metering: Chassis shall feature dedicated tie-
down lugs for flatbed transport and a digital run-time hour meter for
maintenance scheduling.
3.1.4. Power & Electrical:
3.1.4.1. Drive Power: Industrial heavy-duty electric battery bank providing
sufficient capacity for a full 8-hour museum work shift under normal cycling.
3.1.4.2. Charging & Utilities: System shall include an integrated onboard smart
battery charger compatible with standard 120V AC facility power. Platform
shall include a factory-installed, weather-protected 110V AC GFCI electrical
receptacle wired through the scissor stack to power handheld restoration
tools.
3.2. Large Ride-On Industrial Floor Scrubber / Sweeper
The Contractor shall provide a heavy-duty, ride-on industrial combination floor
scrubber/sweeper meeting the following minimum salient characteristics:
-- 2 of 10 --
3.2.1 Cleaning Productivity & Operating Performance:
3.2.1.1 Cleaning Capacity: Theoretical cleaning productivity shall be a
minimum of 115,000 square feet per hour to support continuous
cleaning across wide-span exhibition hangars.
3.2.1.2 Scrub Path: Scrubbing deck cleaning path width shall be a minimum
of 48 inches. Scrub deck shall utilize dual or triple commercial disk
scrub heads.
3.2.1.3 Scrub Down Pressure: System shall feature variable scrub brush
down pressure capable of delivering up to 350 lbs of down pressure to
remove heavy rubber tire marks, fluid residues, and legacy hangar
contaminants.
3.2.1.4 Drive Speed: Variable-speed drive system operating from 0 to 5.5 mph
with operator cruise control.
3.2.1.5 Operational Run Time: Deep-cycle industrial battery pack providing
a verified continuous operating run-time of not less than 5.0 hours
under active scrubbing load.
3.2.2 Debris Sweeping, Dust Cleanup & Water Handling:
3.2.2.1 Wet/Dry Debris Collection: Integrated forward sweeper module with
a solid debris collection hopper capacity of at least 6.0 cubic feet (𝑓𝑓𝑡𝑡 3)
to collect Foreign Object Debris (FOD) prior to wet scrubbing.
3.2.2.2 High-Dump H…