Refrigerated Shaking Incubators

DEPT OF DEFENSE

Notice type
Solicitation
Solicitation #
FA700026Q0065
NAICS
334516
PSC
6640
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 7, 2026
Response due
July 20, 2026
Place of performance
USAF Academy, CO

Description

Minimum Specifications (Salient Characteristics) CLIN 0001: Refrigerated Shaking Incubator meeting or exceeding the following minimum specifications: • Temperature Range (Refrigerated): Must feature active refrigeration cooling. The unit must be capable of maintaining setpoint temperatures from a minimum of 16.0°C up to a maximum of at least 60.0°C. To guarantee stable operation at the low end of the range, the unit's cooling system must have the capability to cool the chamber to at least 15°C below the ambient room temperature. • Control Interface: Must feature a digital microprocessor controller with an LED, LCD, or touchscreen display for precise monitoring of temperature and speed. • Temperature Accuracy: Must maintain high temperature accuracy of at least ±0.1°C to ±0.2°C at 37°C. • Agitation Speed: Shaking speed must be continuously adjustable across a minimum full range of 30 RPM to 300 RPM. • Orbit Diameter: Must have an orbit diameter between 0.75 inches (19 mm) and 1.0 inch (25 mm). • Platform & Capacity: Must be compatible with a universal platform (CLIN 0002) capable of accommodating and securing up to six (6) 1-Liter Erlenmeyer flasks simultaneously, or at least sixteen (16) 250 mL Erlenmeyer flasks simultaneously. • Chamber Material & Maintenance: The interior chamber must be constructed of corrosion-resistant stainless steel to allow for standard laboratory wipe-down and easy cleaning in the event of a flask spill. • Stacking: Must be stackable to at least 2 units high (CLIN 0005). • Power: Must operate on standard US voltage (120V ± 10%, 60Hz) with standard cUL/UL certifications. • Warranty: Must include a standard commercial warranty of at least one (1) year covering parts and labor. CLIN 0002: Universal Platform meeting or exceeding the following minimum specifications: -- 1 of 2 -- Description: Two (2) each, Universal platforms with a minimum physical footprint of 18" x 18" capable of accommodating and securing up to six (6) 1-liter Erlenmeyer flasks simultaneously, or at least sixteen (16) 250 mL Erlenmeyer flasks simultaneously. Must be constructed from corrosion-resistant materials to prevent rusting in high-humidity incubation environments. Must be fully compatible with CLINs 0001, 0003, and 0004. CLIN 0003: 1L Flask Clamps/Holders Description: Four (4) each, 1-liter spring-action Erlenmeyer flask clamps constructed of corrosion-resistant materials. Must include compatible corrosion-resistant mounting hardware to attach each individual clamp securely to CLIN 0002. CLIN 0004: 250 mL Flask Clamps/Holders Description: Twenty (20) each, 250 mL spring-action Erlenmeyer flask clamps constructed of corrosion-resistant materials. Must include compatible corrosion-resistant mounting hardware to attach each individual clamp securely to CLIN 0002. CLIN 0005: Stacking Kit Description: Manufacturer approved stacking kit intended to safely stack 2 refrigerated shaking incubators. Must feature mounting hardware that secures the upper unit's frame directly into the lower unit's chassis frame. The installation of the stacking kit must not block, cover, or impede access to critical rear exhaust vents, refrigeration cooling intake grilles, power plugs, or technical service access panels of either the top or bottom incubator units (CLIN 0001). It must be fully compatible with CLIN 0001. -- 2 of 2 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 334516)