Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan.

DEPT OF DEFENSE

Notice type
Solicitation
Solicitation #
FA520926Q0077
NAICS
335312
PSC
6115
Set-aside
No Set aside used
Posted
November 9, 2026
Response due
November 24, 2026
Place of performance
Zama, JP-14

What this opportunity is

The Department of Defense is soliciting quotes for the replacement and disposal of a 150kVA emergency power diesel generator at Camp Zama, Japan. This opportunity is open to all businesses, as there is no set-aside for small businesses. Contractors must demonstrate relevant experience and provide employees with specific certifications related to emergency power generators and electrical work. Interested parties should note that this is a solicitation notice, indicating that they should track the opportunity rather than submit a bid immediately.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

FA520926Q0077 Attachment 1 STATEMENT OF WORK (SOW) FI-MUE Replace Zama DSN-HHD Generator 78 th Signal Battalion Camp Zama, Japan 24 Aug 2026 -- 1 of 12 -- FA520926Q0077 Attachment 1 1. INTRODUCTION This Statement of Work (SOW) defines the requirements, scope, responsibilities, and deliverables for the replacement and disposal of the 150kVA emergency power diesel generator located on Camp Zama Japan Building 121. 2. SCOPE OF WORK The contractor shall provide all necessary materials, equipment, labor, and services to: 2.1. Decommissioning and Removal of Existing Generator. • Disconnection from the electrical distribution system. • Safe removal of residual fuel and proper disposal as per environmental regulations. • Safe removal of coolant and oil and proper disposal as per environmental regulations. • Disassembly and transport of the existing generator from the site (Bldg. 121, Camp Zama) to an authorized disposal facility. • Removal disposal of old conduits and exhaust piping that cannot be re-used for the new generator system. 2.2. Disposal and Environmental Compliance • Disposal of the generator, engine, batteries, coolant, oils, shall be completed by the contractor utilizing off-base location. • Proper handling and disposal of hazardous materials, including oil, fuel, and battery components. • Contractor shall provide a copy of the receipt of disposal of any hazardous waste to the Government Representative (GR) of this contract for recorded keeping. 2.3. Installation of New Generator • Site preparation, including foundation modifications if required. • Delivery and offloading of the new generator. • Installation and secure anchoring of the generator unit. • Electrical integration with the existing power panel and ATS. Contractor is permitted to reuse existing wires and conduits from Panel L-M-2 to the generator pending they reach without the need for splicing. Splicing of wires is not permitted. • Connection and modification of exhaust system. The contractor may reuse existing exhaust piping to avoid new holes and core drilling of the outside wall. • The contractor shall also utilize all existing air intake ducts, both internal and external, for compatibility. The contractor is encouraged and permitted to re-use the existing fuel piping and radiator exhaust ducting, provided that they are thoroughly inspected, tested, and certified by the contractor to be in fully functional, safe, and leak-free condition prior to the integration with the new generator system. • The existing Stainless Steel Diesel Tank, renewed in 2008 and confirmed serviceable, shall be utilized by the contractor for compatibility with the replacement generator. Technical drawings for this tank are available upon request [4] -- 2 of 12 -- FA520926Q0077 Attachment 1 2.4. Testing and Commissioning • Verification of electrical connections and power output. • Contractor shall conduct a minimum 8-hour load test utilizing site loads as part of the post installation test & commissioning plan. • Contractor shall provide a draft post installation test and commissioning plan to the GR no later than 30 days prior to final acceptance of the new generator system. This test plan will need to be reviewed and approved by the GR prior to being implemented for acceptance. 2.5. Handover and Documentation • Training for facility personnel on new generator operation and maintenance. • The contractor shall submit three (3) sets of work performance and test result reports, as-built drawings, operation manuals, and warranty documents in both English and Japanese, to the GR(78th Signal Battalion/DPW) within 15 calendar days after the work completion date. Such reports shall be submitted in booklet-type and digital forms with catalog cuts/manufacturer drawings of replacement parts. 3. Technical Specifications 3.1. Existing Generator Details (To Be Disposed of) • Capacity: 150 KVA / 120 KW • Voltage Output: 208/120 VAC • Maka/Model: Toyo Denki Seizo / TYND-215 • Fuel Type: Diesel • Frequency: 50 Hz • Current Status: Unserviceable and Obsolete, to be decommissioned 3.2. New Generator Specifications • Capacity: 150 KVA / 120 KW • Voltage Output: 208/120 VAC • Frequency: 50 Hz • Fuel Type: Diesel • Wiring: 3 Phase, 4 Wire Plus 1 Ground. • The new diesel generator shall be fully compatible and connected to the existing ATS inside of B121 Camp Zama. The Contractor is responsible for conducting pre-proposal survey(s) prior to quote submission to confirm that the compatibility of the proposed generator with the existing ATS. • New generator/engine shall come equipped with a water jacket heater to ensure the diesel engine is maintained at a temperature of 40-50 degrees Celsius while in standby mode. • New generator system shall have an output breaker local to the generator to ensure proper isolation for maintenance. • New generator shall have Phase to phase & Phase to neutral power, voltage, and amperage indication gauges/meters affixed to the generator for operational trending. -- 3 of 12 -- FA520926Q0077 Attachment 1 • New generator shall automatically adjust frequency based on load demands to maintain a tight operational tolerance between 49.5 – 50.5 HZ. • New generator shall automatically adjust AVR based on load demands to maintain a tight operational tolerance between + or – 5% of nameplate per ANSI C84.1. (198V to 218V & 114V to 126V) • Sound Level: Compliance with Japanese noise regulations for industrial zones • Environmental Compliance: Meets Japan’s emissions standards for diesel generators • Warranty: This contract shall include an extended 2-year warranty provided either by the contractor or Original Equipment Manufacture (OEM) that covers any repairs or replacement of premature failures of the system or its subcomponents under normal operations. 3.3. Existing Automatic Transfer Switches (ATS) • Building 121 contains two (2) existing Automatic Transfer Switches (ATS) for the emergency power sy…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 335312