Service Air System Revitalization

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
FA9101_Service_Air_System_Revitalization
NAICS
333912
PSC
4310
Posted
November 17, 2026
Response due
November 25, 2026
Place of performance
0, TN

Description

17416-26-001 SOO No: 17416-26-001 27 October 2026 NOT SENSITIVE IRA-26-2125 Page 1 of 6 STATEMENT OF OBJECTIVES (SOO) FOR SERVICE AIR SYSTEM REVITALIZATION 1.0 PURPOSE The purpose of this project is to revitalize a Service Air System at the Arnold Engineering Development Complex (AEDC), located at Arnold Air Force Base, Tennessee. The current service air infrastructure has experienced reduced reliability and capacity due to aging equipment. The goal of this revitalization is to deliver a fully operational, safe, energy-efficient, and modernized compressed air and dry air network. This will be achieved through the engineering, design, procurement, installation, and commissioning of new Ingersoll-Rand (IR) compressed air equipment, alongside the refurbishment and integration of existing system components. 2.0 SCOPE The scope of this initiative encompasses the engineering, system design, procurement, delivery, installation, integration, refurbishment, and commissioning of new and existing service air assets across three primary facility locations: • Building 541 • Building 913 • Building 878 This program entails replacing eleven (11) obsolete IR air compressors, replacing one (1) IR desiccant dryer, relocating and reinstalling an existing compressor, refurbishing six (6) existing IR desiccant dryers, and upgrading associated electrical, piping, and condensate management infrastructure. 3.0 BACKGROUND The Service Air System provides essential compressed air capacity to support facility operations. To maintain this system, several key replacements and system refurbishments are required: • Building 913: Six (6) rotary-screw air compressors require replacement. • Building 878: Four (4) rotary-screw air compressors require replacement. One (1) rotary- screw compressor was replaced in 2020; it is in good working order but must be relocated and integrated into the new facility layout. • Building 541: One (1) obsolete centrifugal air compressor (CENTAC) and one (1) associated desiccant dryer require replacement. • Dryer Revitalization: Six (6) existing Ingersoll-Rand (IR) HB4000 desiccant dryers located in Buildings 913 and 878 require complete refurbishment to restore them to full moisture- removal capacity. -- 1 of 6 -- 17416-26-001 NOT SENSITIVE IRA-26-2125 Page 2 of 6 The critical assets involved in this program are outlined below: Current Model Number Current Serial Number Location Project Action Required HPE300-2S EE2816U08074 Bldg. 913 Replace with Water-cooled RS220IE HPE300-2S EE2817U08084 Bldg. 913 Replace with Water-cooled RS220IE HPE300-2S EE3262U11101 Bldg. 913 Replace with Water-cooled RS220IE HPE300-2S EE3261U11101 Bldg. 913 Replace with Water-cooled RS220IE HPE300-2S EE3260U11098 Bldg. 913 Replace with Air-cooled RS220IE HPE300-2S EE3263U11102 Bldg. 913 Replace with Air-cooled RS220IE HPE300-2S EE3033U09107 Bldg. 878 Replace with Air-cooled RS220IE HPE300-2S EE3032U09106 Bldg. 878 Replace with Air-cooled RS220IE RS220ie MOX1002634 Bldg. 878 Relocate and Reinstall (Keep Unit) HPE300-2S EE3030U09104 Bldg. 878 Replace with Water-cooled RS220IE HPE300-2S EE3031U09106 Bldg. 878 Replace with Water-cooled RS220IE HB4000 301050 Bldg. 913 Refurbish to Full Capacity HB4000 504074 Bldg. 913 Refurbish to Full Capacity HB4000 504075 Bldg. 913 Refurbish to Full Capacity HB4000 319459 Bldg. 878 Refurbish to Full Capacity HB4000 319461 Bldg. 878 Refurbish to Full Capacity HB4000 301050 Bldg. 878 Refurbish to Full Capacity 1CV14M2 (Centrifugal) M97-9566 Bldg. 541 Replace with Water-cooled RS220IE EHD1000-FGH 97DEHD2095 Bldg. 541 Replace with 1800SCFM Desiccant Dryer Various (PS- 1125 / PSG-60) Various Bldg. 913/878/541 Integrate and Revitalize Condensate Systems 4.0 PROGRAM GOALS AND PERFORMANCE OBJECTIVES The government's primary goals are to achieve a highly reliable service air footprint, minimize operational downtime during installation, and optimize the total cost of ownership. The contractor shall propose a technical approach to meet the following objectives: Objective 1: Deliver Modernized and Reliable Air Generation Capacity • Establish Baseline Capacity: Replace compressors with modern, highly efficient IR equivalents that restore nominal base compressed air capabilities. The proposed configuration should meet or exceed the following footprint specifications: • Water-cooled Compressors (7 Units): Replacing Compressors 1-4 in Bldg. 913; Compressors 10-11 in Bldg. 878; and the Centrifugal Compressor in Bldg. 541. -- 2 of 6 -- 17416-26-001 NOT SENSITIVE IRA-26-2125 Page 3 of 6 • Air-cooled Compressors (4 Units): Replacing Compressors 5-6 in Bldg. 913 and Compressors 7-8 in Bldg. 878. • Asset Reuse Optimization: Successfully relocate, reinstall, and integrate the newly inherited compressor (S/N: MOX1002634) within the updated layout of Bldg. 878, ensuring its performance is optimized alongside the new installations. • Form, Fit, and Function (FFF) Compatibility: The proposed replacement IR compressors, desiccant dryers, and auxiliary skid components shall match or fit within the existing spatial, structural, mechanical, and electrical footprints of Buildings 541, 878, and 913. The contractor's solution shall minimize structural or architectural facility modifications, utilizing existing equipment pads, access ways, and utility penetration points wherever technically viable. Objective 2: Optimize Air Quality and Dryness Capabilities • Dryer Replacement: Implement a highly reliable desiccant air drying system in Bldg. 541 capable of handling at least an 1800 SCFM flow rate to ensure downstream air meets dewpoint standards. • Desiccant Dryer Revitalization: Fully refurbish all six (6) existing HB4000 desiccant dryers (3 in Bldg. 913 and 3 in Bldg. 878) to restore them to original equipment manufacturer (OEM) operational efficiency and capacity. Objective 3: Seamless Integration with Base Infrastructure • Utility Interconn…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 333912