Skip to content

Open for responses

Sterile Compounding Services

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
36C25727Q0032
NAICS
541380
PSC
Q301
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted
November 16, 2026
Response due
November 24, 2026
Place of performance
TX

Description

PERFORMANCE WORK STATEMENT South Texas Veterans Health Care System Certification of Sterile Compounding Services South Texas Veterans Health Care System Audie L. Murphy Memorial VA Hospital 7400 Merton Minter Blvd. San Antonio, TX BACKGROUND: The United States Pharmacopeia (USP) establishes standards for cleanroom design, environmental monitoring, and competencies for the preparation, handling, and storage of Compounded Sterile Preparations (CSPs). The Joint Commission (TJC) established new Medication Compounding (MC) standards for non-sterile and sterile compounded preparations which are based on USP standards. Additionally, the Food and Drug Administration (FDA) has the authority to inspect VA medical facilities using the USP standards. VHA Directive 1108.12, Management and Monitoring of Pharmaceutical Compounded Sterile Preparations, dated February 14, 2024, defines organizational responsibility for USP <797> and USP <800> standards for cleanroom design and engineering controls, environmental monitoring and cleaning of primary and secondary engineering controls, and the core competencies for personnel involved in the processes of compounding sterile preparations including HDs (both sterile and nonsterile dosage form preparations). It is VHA policy that each VA medical facility that provides CSPs have a pharmaceutical CSP program in place that conforms to the standards in USP Chapter <797> “Pharmaceutical Compounding‐Sterile Compounding” and USP <800> “Hazardous Drugs – Handling in Healthcare Settings.” According to VHA Directive 1108.12, and that all VA medical facilities must establish a separate and dedicated contract for all applicable USP <797> and USP <800> CSP performance evaluations, testing, and certifications requirements. OBJECTIVE: South Texas Veterans Healthcare System seeks a contractor, for testing and certification of the Audie L. Murphy Memorial VA Hospital Pharmacy Service’s primary engineering controls (PECs) and secondary engineering controls (SECs) used for preparation of Compounded Sterile Preparations (CSPs) in addition to testing of compounding personnel for aseptic technique by gloved fingertip and thumb sampling and media fill testing. PECs include biological safety cabinets (BSCs) and laminar airflow workstations (LAFWs) hoods. Testing and certification will be completed in accordance with United States Pharmacopeia (USP) Chapter <797> and <800> guidelines using Controlled Environment Testing Association (CETA) Certified National Board of Testing (CNBT) certified individuals/companies to establish consistent PEC certification procedures using the Certification Guide for Sterile Compounding Facilities CAG-003-2006. USP <797> implies Controlled Environment Testing Association (CETA) Controlled Applications Guides (CAGs) “or equivalent” may be used. CETA CAGs define certification procedures to assess the PEC is performing and operating as designed to maintain a sterile environment for the preparation of CSPs. According to VHA Directive 1108.12, VA adopted CETA CAGs as the mandatory standard; no “equivalent” standards may be used. All vendors used to conduct primary and secondary engineering controls certifications/assessments must be registered with CETA, as Registered Certified Professionals for Sterile Compounding Facilities (RCP SCF). DEFINITIONS: Anteroom. An anteroom is an International Organization for Standardization (ISO) Class 8 or cleaner room with fixed walls and doors where personnel’s hand hygiene, garbing procedures and other activities that generate high particulate levels may be performed. The anteroom is the transition room between the unclassified area of the facility and the buffer room. NOTE: An ISO Class 7 anteroom is required when compounding hazardous drugs in compliance with USP. Biological Safety Cabinet. A Biological Safety Cabinet (BSC) is a ventilated cabinet used for preparation of hazardous CSPs for personnel, product, and environmental protection having an open front with inward airflow for personnel protection, downward high-efficiency particulate air (HEPA)-filtered laminar airflow for product protection, and HEPA-filtered exhausted air for environmental protection. A BSC is an example of a Containment Primary Engineering Control (C-PEC). Buffer Room. A Buffer room is an ISO Class 7 or cleaner room with fixed walls and doors where PEC(s) that generate and maintain an ISO Class 5 environment are physically located. The buffer room may only be accessed through the anteroom or another buffer room. Classified area. A classified area is one that maintains an air quality classification based on the ISO standards (also known as ISO class). Cleanroom Suite. A cleanroom suite is a room with a classified buffer and anteroom in which the concentration of airborne particles is controlled to meet a specified airborne particulate cleanliness class. Microorganisms in the environment are monitored so that a microbial level for air and surface are not exceeded for a specified cleanliness class. Compounded Sterile Preparation. A compounded sterile preparation (CSP) is a formulation intended to be sterile that is created by combining, diluting, pooling, or otherwise altering a drug product or bulk drug substance. A product produced by reconstituting a conventionally manufactured product for an individual patient strictly in accordance with the directions contained in the approved labeling provided by the product manufacturer is not considered a CSP within the standards of USP. Containment Primary Engineering Control. A Containment Primary Engineering Control (C-PEC) is a type of Primary Engineering Control (PEC) that is a ventilated device designed and operated to minimize worker environmental exposures to hazardous drugs by controlling emissions of airborne contamination. Controlled Environment Testing Association Controlled Application Guide. Controlled Environment Testing Associ…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 541380