What this opportunity is
The Department of Defense is soliciting proposals for a Multiple Award Construction Contract (MACC) at Tinker Air Force Base in Oklahoma, classified under NAICS 236210. This opportunity is set aside for small businesses, allowing partial participation. Interested contractors should note that the solicitation includes updated evaluation criteria and instructions, with a proposal due date extended to November 30, 2026, at 1 PM. Tracking this solicitation is essential, as it involves multiple amendments and changes that require careful review of the provided documents.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
Tinker AFB Tinker General Requirements
SECTION 01 35 26
GOVERNMENTAL SAFETY REQUIREMENTS
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by
the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 52.2 (2017) Method of Testing General
Ventilation Air-Cleaning Devices for
Removal Efficiency by Particle Size
AMERICAN SOCIETY OF SAFETY PROFESSIONALS (ASSP)
ANSI/ASSP A10.34 (2021) Protection of the Public on or
Adjacent to Construction Sites
ANSI/ASSP A10.44 (2020) Control of Energy Sources
(Lockout/Tagout) for Construction and
Demolition Operations
ANSI/ASSP Z490.1 (2016) Criteria for Accepted Practices in
Safety, Health, and Environmental Training
ASTM INTERNATIONAL (ASTM)
ASTM D6245 (2012) Using Indoor Carbon Dioxide
Concentrations to Evaluate Indoor Air
Quality and Ventilation
ASTM D6345 (2010) Standard Guide for Selection of
Methods for Active, Integrative Sampling
of Volatile Organic Compounds in Air
ASTM F855 (2020) Standard Specifications for
Temporary Protective Grounds to Be Used on
De-energized Electric Power Lines and
Equipment
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
IEEE 1048 (2016) Guide for Protective Grounding of
Power Lines
IEEE C2 (2023) National Electrical Safety Code
INTERNATIONAL SAFETY EQUIPMENT ASSOCIATION (ISEA)
ANSI/ISEA Z89.1 (2014; R 2019) American National Standard
for Industrial Head Protection
October 2026 Page 1 Section 01 35 26
-- 1 of 17 --
Tinker AFB Tinker General Requirements
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA Z535.2 (2011; R 2017) Environmental and Facility
Safety Signs
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 51B (2024) Standard for Fire Prevention During
Welding, Cutting, and Other Hot Work
NFPA 70 (2023; ERTA 1 2024; TIA 24-1) National
Electrical Code
NFPA 70E (2024) Standard for Electrical Safety in
the Workplace
NFPA 241 (2022) Standard for Safeguarding
Construction, Alteration, and Demolition
Operations
NFPA 306 (2024) Standard for the Control of Gas
Hazards on Vessels
SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION
(SMACNA)
ANSI/SMACNA 008 (2007) IAQ Guidelines for Occupied
Buildings Under Construction, 2nd Edition
U.S. ARMY CORPS OF ENGINEERS (USACE)
EM 385-1-1 (2024) Safety -- Safety and Occupational
Health (SOH) Requirements
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
10 CFR 20 Standards for Protection Against Radiation
29 CFR 1910 Occupational Safety and Health Standards
29 CFR 1915 Confined and Enclosed Spaces and Other
Dangerous Atmospheres in Shipyard
Employment
29 CFR 1919 Gear Certification
29 CFR 1926 Safety and Health Regulations for
Construction
49 CFR 173 Shippers - General Requirements for
Shipments and Packagings
CPL 2.100 (1995) Application of the Permit-Required
Confined Spaces (PRCS) Standards, 29 CFR
1910.146
October 2026 Page 2 Section 01 35 26
-- 2 of 17 --
Tinker AFB Tinker General Requirements
1.2 FORMS
USACE Engineer Forms (ENG Form) cited in this specification may be
obtained at the following link:
https:\\www.publications.usace.army.mil/USACE-Publications/Engineer-Forms/
1.3 DEFINITIONS
The following definitions are for the convenience of the reader. If there
is a referenced document in the text of this specification section, that
is the document that should define terms for that paragraph. If further
clarification is needed, contact the Contracting Officer.
1.3.1 Site Safety and Health Officer (SSHO)
A Contractor Employee that is responsible for overseeing and ensuring
implementation of the prime Contractor's Safety and Occupational Health
(SOH) program according to the Contract, EM 385-1-1, applicable federal,
state, and local requirements.
1.3.1.1 Level One SSHO
A designated employee with full-time SOH responsibility that meets and
follows the requirements of EM 385-1-1.
1.3.1.2 Level Two SSHO
A designated employee with Level Two SSHO responsibility that meets and
follows the requirements of EM 385-1-1. Level Two SSHOs cannot be
assigned to projects that have a residual Risk Assessment Code (RAC) of
high or extremely high.
1.3.1.3 Level Three SSHO
A designated Qualified Person or Competent Person with SOH responsibility
that meets and follows the requirements of EM 385-1-1. Level 3 SSHOs
cannot be assigned to projects that have a residual RAC of high or
extremely high.
1.3.1.4 Alternate SSHO
An employee that meets the definition of the contract-required level SSHO,
but is not the primary SSHO.
1.3.2 Competent Person (CP)
The CP is a person designated in writing, who, through training, knowledge
and experience, is capable of identifying, evaluating, and addressing
existing and predictable hazards in the working environment or working
conditions that are unsanitary, hazardous, or dangerous to personnel, and
who has authorization to take prompt corrective measures to eliminate them.
1.3.3 Qualified Person (QP)
The QP is a person designated in writing, who, by possession of a
recognized degree, certificate, or professional standing, or extensive
knowledge, training, and experience, has successfully demonstrated their
ability to solve or resolve problems related to the subject matter, the
October 2026 Page 3 Section 01 35 26
-- 3 of 17 --
Tinker AFB Tinker General Requirements
work, or the project.
1.4 SUBMITTALS
Government Acceptance or Approval does not remove responsibility from the
Contractors for their actions or liability.
Government approval is required for submittals with a "G" classification.
Submittals not having a "G" classification are for information only.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-01 Preconstruction Submittals
Accident Prevention Plan (APP) Design; G
Accident Prevention Plan (APP) Construction; G
SD-06 Test Reports
Accident Reports; G
LHE In…
Source: SAM.gov, as posted. Verify the current solicitation before responding.