USCGC HUDSON TANK, POTABLE WATER CLEANING AND INSPECTION
HOMELAND SECURITY, DEPARTMENT OF
Notice type
Combined Synopsis/Solicitation
Solicitation #
52050PR260000307
NAICS
562998
PSC
J046
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 25, 2026
Response due
July 15, 2026
Place of performance
FL
What this opportunity is
The Department of Homeland Security is buying potable water tank cleaning and inspection services for the USCGC HUDSON. This procurement is set aside for total small businesses. The work will be performed in Florida. As a combined synopsis and solicitation, this notice indicates that proposals will be accepted in response to this announcement.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
USCGC HUDSON (WLIC 801)
SPECIFICATION FOR DOCKSIDE REPAIRS
FY2026
Developed By: Erik C Elasik
(Rev-0, 15 October 2025)
-- 1 of 26 --
USCGC HUDSON (WLIC-160A) DOCKSIDE AVAILABILITY FY2026
15 (Rev-0)
12314_ESD_0423_FLT
REC_12314_FLT160’ WLIC ‘A’ Class (ALL) (0611)
WORK ITEM 1: Tanks, Potable Water, Clean and Inspect
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to clean and inspect the following
tank(s):
TABLE 1 - TANKS
TYPE OF TANK LOCATION CAPACITY - 95%
(GALLONS)
LOW SUCTION
(GALLONS)
Potable Water 2-34-1-WW 3,306 100
Potable Water 2-34-2-WW 3,306 100
Potable Water 2-44-1-WW 1,779 50
Potable Water 2-44-2-WW 1,779 50
Potable Water 2-49-1-WW 3,551 100
Potable Water 2-49-2-WW 3,551 100
1.2 Government-furnished property.
None.
2. REFERENCES
COAST GUARD DRAWINGS
Coast Guard Drawing 160 WLIC 103-002, Rev A, Booklet of General Plans
COAST GUARD PUBLICATIONS
-- 2 of 26 --
USCGC HUDSON (WLIC-160A) DOCKSIDE AVAILABILITY FY2026
16 (Rev-0)
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022,
General Requirements
OTHER REFERENCES
American National Standards Institute/NSF International (ANSI/NSF) 61, 2015, Drinking Water
System Components - Health Effects
American National Standards Institute/American Water Works Association (ANSI/AWWA)
C652, 2011, Disinfection of Water-Storage Facilities
3. REQUIREMENTS
3.1 General.
3.1.1 CIR.
None.
3.1.2 Tech Rep.
Not applicable.
3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance
with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).
3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000,
(Interferences). Known interferences include, but are not limited to the following:
• Fluid contents
• Piping
• RO system components
• Deck grating.
NOTE
Coast Guard personnel will operate all shipboard machinery and equipment.
3.2 Operational test, initial. Prior to commencement of work, the Contractor must witness Coast Guard
personnel perform an initial operational test of the equipment listed below to demonstrate existing
operational condition. Submit a CFR.
• TLI
3.3 Plug log. The Contractor must keep a written record of all plugs put in any tanks vents. A separate list
must be kept for each tank being entered.
-- 3 of 26 --
USCGC HUDSON (WLIC-160A) DOCKSIDE AVAILABILITY FY2026
17 (Rev-0)
3.3.1 Ensure that all plugs are removed from each tank upon completion of work in the tank.
3.3.2 Ensure the plug log is available to the Coast Guard inspector when the inspector is performing his
close-out inspection on each tank.
3.4 Tank content removal. The Contractor must remove and dispose of all fluids and/or residues in
accordance with all applicable Federal, state, and local regulations. The Contractor must notify the
Dockmaster prior to filling or draining the potable water tank(s), when this item is being executed in a
drydock availability. The Contractor must refer to Coast Guard drawings 160 WLIC 103-002 for
guidance.
3.5 Tank cleaning. The Contractor must remove tank cover(s); clean tank interior surfaces free of all
foreign materials, such as sediment, sludge and bacterial growth. Remove all persistent residues, taking
care not to damage any tank coating system. Remove cleaning media and residues continuously from the
tank during the washing process. Remove any residual wash media and wipe up residual moisture with
clean lint-free cloths. Collect, contain, and dispose of all wash media, residues, and cleaning materials in
accordance with all Federal, state, and local regulations.
3.6 Inspection. The Contractor must visually inspect all tank interior surfaces, including, but not limited
to bulkheads, floor and overhead plating, structural members, manhole cover surfaces, fasteners and
gasket seating surfaces. Complete the “Tank and Void Assessment Form” (found in the Work Item titled
“General Requirements”) and submit via CFR. Electronic PDF version of this form will be furnished by
the COR upon request. Include the following, as applicable:
• Tank structural condition.
• Inaccessible areas, if any.
• Condition of tank coating, including measurements taken, percentage, location, and type of
coating failure.
• Tank level indicator (TLI) and/or float switch condition (if applicable).
• Sounding tube and striker plate condition.
• Suction and discharge piping condition.
• Fastener material and condition.
3.7 Tank closing. The Contractor must notify the COR at least 24 hours prior to closing the tank(s) and
ensure tank closure is accomplished in the presence of the Coast Guard Inspector. After satisfactory
inspection by the Coast Guard Inspector, and completion of all authorized repairs, close tank manhole
cover(s) with new gasket material conforming to ANSI/NSF 61. Renew all stud cotton grommets (as
applicable) upon reinstallation of manhole cover(s).
3.7.1 The Contractor must renew 100% of nuts and washers.
3.8 Tank disinfecting. After all other work involving the potable water system and tank closing have been
completed, the Contractor must disinfect and treat the affected potable water tank(s) and associated
disturbed piping and components, as necessary, to meet or exceed the requirements of AWWA C652.
After tank disinfecting, remove and dispose of all treated water in accordance with all Federal, state and
local regulations. Ensure that no one enters the tanks once disinfection is completed. Submit CFR
providing confirmation that disinfection of tank(s) and associated potable water system disturbed piping
-- 4 of 26 --
USCGC HUDSON (WLIC-160A) DOCKSIDE AVAILABILITY FY2026
18 (Rev-0)
and components has been completed and certifying that all sampling and testing is negative for coliform
organisms.
NOTE
Coast Guard personnel will operate all shipboard machinery and equipment.
3.9 Operational test, post repairs. After completion…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 562998)
J045--Drain and Grease Trap Maintenance
VETERANS AFFAIRS, DEPARTMENT OF · Combined Synopsis/Solicitation · due July 28, 2026
ANC Solid Waste W91QV126RA018
DEPT OF DEFENSE · Solicitation · due July 24, 2026
NS Graywater Service
DEPT OF DEFENSE · Solicitation · due July 24, 2026
ANC Solid Waste W91QV126RA018
DEPT OF DEFENSE · Solicitation · due July 24, 2026
Grease Trap Clean Out
DEPT OF DEFENSE · Presolicitation · due August 3, 2026
J045--Drain and Grease Trap Maintenance
VETERANS AFFAIRS, DEPARTMENT OF · Combined Synopsis/Solicitation · due July 28, 2026