Skip to content

Open for responses

W065--medical-grade oxygen cylinders/tanks

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Special Notice
Solicitation #
36C24127Q0091
NAICS
532490
PSC
W065
Posted
November 24, 2026
Response due
November 30, 2026

Description

The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Airgas USA, LLC, for the following requirement: Statement of Work General: The contractor will provide delivery of all requirements for individual compressed gas cylinders/tanks to the locations listed in this document. Period of Performance: base year plus one option year Base year: January 1, 2027 - December 31, 2027 Option year one: January 1, 2028 December 31, 2028 Intended Use: To meet the needs for patients requiring oxygen therapy during transport to different locations of the Boston VA Healthcare System within the facilities. The requirement of the following are estimated amount of each specific size, type of material the cylinder is manufactured of, cylinders with integrated regulators and handles. Integrated valve stem regulator with the aluminum cylinder are utilized throughout Boston Healthcare System. Boston VA Healthcare System requires that all of the hospital transport cylinders be light weight cylinders with integrated regulator with wide handle that is secured to the regulator that extends upward for ease of carrying. The integrated regulator must be able to deliver a flow rate of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15, 25 liters per minute flow. The regulator also must provide a 50 psi outlet port to connection to equipment if needed. Boston VA Healthcare System requires that of the hospital MR compatible transport cylinders be light weight cylinders with integrated regulator with wide handle that is secured to the regulator that extends upward for ease of carrying. The integrated regulator must be able to deliver a flow rate of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15, 25 liters per minute flow. The regulator also must provide a 50 psi outlet port to connection to equipment if needed. Boston VA Healthcare System requires that all H cylinders are made of Steel with the Diameter Index Safety System. These cylinders are utilized for Emergency Back Up during an oxygen failure or shut down. Place of Performance: West Roxbury VA Medical Center 1400 VFW Pkwy, West Roxbury, MA 02132 Jamaica Plain VA Medical Center 150 South Huntington Ave, Boston, MA 02130 Brockton VA Medical Center 940 Belmont St Brockton, MA 02301 Day and Hours of Operation: West Roxbury VA Medical Center: M-F 0800-1600 or after regular duty hours by calling the respiratory care department for access. Jamaica Plain VA Medical Center: M-F 0800-1600 Brockton VA Medical Center: M-F 0800-1600 Performance Requirements: The contractor must be able to supply the facilities listed above with the medical grade compressed gases listed in Section 8 weekly. Specifically- deliveries are to be made to West Roxbury campus every Monday and Thursday without fail excluding holidays at which point a needs assessment will be completed and the company will push delivery to the next business day. Deliveries will be made twice per week at the Jamaica Plain campus every Monday and Thursday following the same protocol as West Roxbury. Deliveries will be made twice per week at the Brockton campus following same scheduling and protocol as West Roxbury. The contractor will respond to emergency calls within 2 hours. The contractor shall respond to non-emergency call within 24 hours or the next business day. The contractor shall repair all minor cylinder leaks detected and provide a full report of leak tests and any leaks repaired to the Contracting Officer s Representative (COR). Patient and occupation safety require that all tanks meet all regulatory guidelines and the tanks and regulators allow continuous oxygen flow between regulator settings. Safety features include: Oxygen flow that does not stop if the regulator is placed between two numbers. Integrated valve and regulator that is built into tank and doesn t need to be installed by staff. Single valve tank. No tanks with two valves, this is a human factor safety risk. National Center for Patient Safety discourages any two valve tanks. Rupture disk relief valve. 50 PSI DISS outlet that delivers up to 200 lpm if needed for mechanical ventilator device. Invoices: Invoicing is required to be submitted per delivery. Payment will be made upon receipt of a properly prepared detailed invoice, prepared by the contractor, validated by the contracting officer s representative (COR) and submitted. A properly prepared invoice will contain: Invoice number and date Contractor s name and address Contract number Accurate purchase order number Itemized supply or service provider Total amount due Medical Gases and Supplies to be Provided: West Roxbury Location Furnish and maintain 3429 E cylinder made of aluminum with integrated valve. Furnish and maintain 483 MRI safe E cylinder made of aluminum with integrated valve. Furnish and maintain 43 H cylinder made of steel using DISS system. Jamaica Plain Location Furnish and maintain 3429 E cylinder made of aluminum with integrated valve. Furnish and maintain 33 H cylinder made of steel using DISS system Brockton Location Furnish and maintain 3429 E cylinder made of aluminum with integrated valve Furnish and maintain 33 H cylinder made of steel using DISS system The NAICS code for this requirement is 532490. Airgas USA, LLC is the only vendor capable of providing the required services as they presently have liquid oxygen tanks located at all three(3) facilities within the Boston Healthcare System; they also have backup reserves at these facilities (3 in Brockton, 1 in West Roxbury, 1 at JP). The station tanks are owned by Airgas USA, LLC and proprietary to their oxygen supply. Due to liability issues, it is not permissible or legal for a contractor other than Airgas to fill or maintain the tanks owned by Airgas. Airgas provides annual inspections and preventative maintenance on the station tanks at no additional cost to the government and prov…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 532490