What this opportunity is
The Department of Defense is seeking maintenance and repair services for Material Handling Equipment (MHE) at DLA Disposition Services in Anchorage, Alaska, under a combined synopsis/solicitation (SP4510-27-Q-1005). This opportunity is open to all businesses, as it is not set aside for small businesses, although the NAICS code is 811310, which has a small business size standard of $12.5 million. Interested vendors should note that quotes are due by 03:00 PM (EST) on December 11, 2026, and all inquiries must be submitted via email by November 27, 2026.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
1
PERFORMANCE WORK STATEMENT (PWS)
FOR
DEFENSE LOGISTICS AGENCY (DLA)
DISPOSITION SERVICES (DS)
ANCHORAGE
MATERIAL HANDLING EQUIPMENT (MHE)
MAINTENANCE SERVICES
-- 1 of 17 --
2
TABLE OF CONTENTS
1. INTRODUCTION
2. PREVENTIVE MAINTENANCE (PM)
3. CORRECTIVE MAINTENANCE (CM)
4. PLACE OF PERFORMANCE OF SERVICES
5. FEDERAL HOLIDAYS
6. BASE ACCESS & SECURITY
7. USG FURNISHED PROPERTY, MATERIALS, EQUIPMENT, AND UTILITIES
(GFP/M/E/U)
8. CONTRACTOR FURNISHED PROPERTY, MATERIALS, EQUIPMENT, AND
SERVICES (CFP/M/E/S)
9. ACCEPTABLE PERFORMANCE LEVELS (APLs)
10. SPILL RESPONSIBILITY
11. INVOICING INFORMATION
12. CONTRACT MINIMUM/MAXIMUM
-- 2 of 17 --
3
1. INTRODUCTION:
a. Defense Logistics Agency (DLA) Disposition Services (DS) is a Major Subordinate
Command (MSC) of DLA with the responsibility of disposing and reutilizing the
United States Government (USG) Department of War (DoW) excess and surplus
property generated by the military services. This is accomplished through
reutilization to other DoW activities, transfer to other Federal agencies, donation to
authorized state and local organizations, sale to the public, or ultimate disposal
through abandonment or destruction. The headquarters for DLA DS is located in
Battle Creek, Michigan.
b. DLA DS Anchorage requires the use of various pieces of Material Handling
Equipment (MHE) during daily operations in support of the military services.
Preventive Maintenance (PM) and Corrective Maintenance (CM) services for MHE
within DLA DS Anchorage are critical to ensure MHE is always operational.
Without timely, efficient, and effective PM and CM services, the DLA DS Anchorage
site will be impacted to a point where we are unable to support our customers.
c. This is a Firm Fixed Price (FFP) time and materials contract which consists of a
performance period of one (1) 12-month base period and two (2) 12-month option
periods. The total contract length shall not exceed three (3) years.
d. The equipment associated with this PWS is listed in Attachment 3 and is subject to
change throughout the contract based on life cycle management of the equipment.
Should the equipment change, Attachment 3 - Equipment List_Anchorage MHE will
be updated by the Contracting Officer (KO) and provided to the Contractor.
e. The Contractor shall provide all personnel, equipment, tools, electronic functional test
equipment, materials, supervision, and quality control necessary to perform, PM, CM,
Annual testing requirements, and other services as defined in this PWS.
f. Upon coordination with PM or CM services, the Contractor shall be required to report
to requesting DLA DS location’s main office to sign in prior to conducting any
services under this contract.
g. Any reference to Contractor throughout this PWS refers to the Contractor, or
Subcontractor, should one be utilized. The Contractor is solely responsible for all
associated work to be completed In Accordance With (IAW) the PWS.
h. The Contractor shall use lock-out/tag-out procedures as necessary for any piece of
equipment receiving any type of service. The Contractor shall verify and confirm
proper clearing procedures prior to returning operational control of the piece of
equipment to the USG.
-- 3 of 17 --
4
i. This Contract includes electric powered equipment, the associated batteries, and
charging stations are part of the required PM and CM maintenance activities.
2. PREVENTIVE MAINTENANCE (PM):
The Contractor shall:
a. Perform at a minimum; One (1) PM service per item listed on the equipment listing
Attachment 3. When each initial Contract Line-Item Number (CLIN) is ordered per
equipment item, the PM may require any or all of the following: all lower-level
maintenance checks and services performed IAW the Original Equipment
Manufacturer (OEM) manual, load test on all load carrying equipment (as
applicable), a Limited Technical Inspection (LTI) and/or as specifically requested by
the Contracting Officers Representative (COR). Additional PMs may be requested by
the COR as required by the OEM Manuel.
i. The LTI shall include but is not limited to a thorough inspection of the electrical
charging equipment and stations for electric powered equipment, engine,
transmission, other major components, controls, mast, cables, chains, hoses,
electrical, air, and hydraulic systems to determine the disposition of the
equipment. The inspection shall include a check of all fluids and fittings and a
chassis lube.
b. Ensure all PM services are completed IAW the OEM manual’s specifications. When
pricing PM services on the Price Schedule (PS), the Contractor shall include the costs
of the following items, but are not limited to: oil, grease/lubricants, Diesel Exhaust
Fluid (DEF), antifreeze, battery fluid (water levels, testing, etc.), air filters, fuel
filters, fittings, inspections and includes normal wear parts (light bulbs, windshield
wipers, etc.) as requested with PM services. Electric equipment shall include battery
and charging station checks (see OEM manual). Parts requiring replacement that
were identified during/after PM will be charged utilizing CM.
c. Perform a fork inspection with each PM IAW the American National Standards
Institute/Industrial Trucks Standards Development Foundation (ANSI/ITSDF).
Standards can be located at the following link: www.itsdf.org.
d. Notify the Contracting Officer Representative (COR) two (2) business days prior to
arrival with the date and time intended to arrive to perform PM services.
e. Start the PM service within five (5) business days of notification. Complete all PM
services within ten (10) business days from the start of the PM service unless
otherwise coordinated with the COR. If the service cannot be completed in this time
frame the Contractor will submit a written justification on company letterhead with a
timeline for completing the PM.
-- 4 of 17 --
5
f. Perform PM service as appropriate on the associated battery, cables, and charging
unit when a CLIN for an Electric item is ordered.
g…
Source: SAM.gov, as posted. Verify the current solicitation before responding.