Open for responses
Electric Power Resiliency Building 56
DEPT OF DEFENSE
Notice type
Combined Synopsis/Solicitation
Solicitation #
SP330027Q0012
NAICS
238210
PSC
Z2GZ
Set-aside
Small Business Set Aside - Total
Posted
November 16, 2026
Response due
December 9, 2026
Description
Amendment 0003 is being issued to change the original SF1449 cover page to correct Block 8 from 12/07/2026 to 12/09/2026 as provided for in the rest of the solicitation. Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Open opportunities in NAICS 238210
Forest Service - Solar Batteries Frenchman Work Center
AGRICULTURE, DEPARTMENT OF · Combined Synopsis/Solicitation · due November 28, 2026
J061--TVHS Generator PM/Bank Testing Base+4
VETERANS AFFAIRS, DEPARTMENT OF · Combined Synopsis/Solicitation · due December 9, 2026
BPAs for Conference Rooms and Audio Visual Systems
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due November 30, 2026
Contractor to Relocate Customer Repeater system and complete tasks listed on the attached Scope of Work (SOW) at the Watervliet Arsenal, NY.
DEPT OF DEFENSE · Solicitation · due November 23, 2026
N062--FY27 Installation of Illuminated Exit Signs SOLICITATION EXTENSION
VETERANS AFFAIRS, DEPARTMENT OF · Presolicitation · due November 19, 2026
IDIQ JOC TOTAL SMALL-BUSINESS SET-ASIDE FOR ELECTRICAL AND OTHER WIRING INSTALLATION PROJECTS AT VARIOUS GOVERNMENT FACILITIES LOCATED WITHIN THE MARINE CORPS LOGISTICS BASE BARSTOW, MARINE CO
DEPT OF DEFENSE · Solicitation · due November 19, 2026