Ft. Bliss Kitchenette Remodeling - BLDG 2447
DEPT OF DEFENSE
Notice type
Solicitation
Solicitation #
W911RX26BA006
NAICS
236220
PSC
Z2FC
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 25, 2026
Response due
July 28, 2026
Place of performance
Fort Bliss, TX
What this opportunity is
The Department of Defense is buying kitchenette remodeling services for BLDG 2447 at Ft. Bliss in Texas, classified under NAICS code 236220. This opportunity is set aside for total small businesses. As a solicitation notice, small businesses should track this opportunity to prepare for a potential bid.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
E N C O N International, Inc.
Engineering, Environmental, & Technical Services
June 23, 2008
Mr. Henry Wilson Phone: (915) 568-2300
Asbestos & Lead Manager Fax: (915) 568-4304
DPW, Bldg. 777
Fort Bliss, TX 79916
RE: SUBMITTAL OF ASBESTOS & LEAD SURVEY REPORTS
Ft. Bliss Bldg. # 2447
ENCON Project #103-08-094
Dear Mr. Wilson,
This document summarizes the Asbestos & Lead Survey Report for the subject facility. The below-listed
information was utilized to complete the Scope of Work Tasks:
Project Location and/or Room No. Whole Bldg.
Brief SOW:
Performed sampling prior to demolition or renovation activities.
ASBESTOS – The sample collection and subsequent laboratory analytical results indicated that
asbestos was not identified in the sampled building materials.
LEAD – Results indicate that twenty-six (26) of the one hundred fifty-two (152) XRF readings tested
at or above the limit of 0.3 mg/cm2
Technical Summary Were
Found
Were
Not
Found
Not
Tested
1. Asbestos Containing Materials (>1 %) X
2. Lead Based Paint Materials X
Contact me with any technical questions, or follow-up needs that you may have.
Sincerely:
Alex Woelper P.E.
Project Manager
Attachments:
Asbestos & Lead Survey Reports
-- 1 of 40 --
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740
Engineering, Environmental & Technical Services
ASBESTOS SURVEY REPORT
BUILDING 2447
FORT BLISS, TEXAS 79916
Prepared for:
Mr. Henry Wilson, P.E.
DPW
Building 777
Fort Bliss, Texas 79916
Prepared by:
ENCON International, Inc.
7307 Remcon Circle,
Suite 103
El Paso, Texas 79912
Date of Inspection:
June 12, 2008
ENCON Project No. 103-08-094
E N C O N INTERNATIONAL, INC.
-- 2 of 40 --
Engineering, Environmental & Technical Services
June 17, 2008
Mr. Henry Wilson, P.E. Phone: (915) 568-2300
Asbestos & Lead Manager Via email & hand delivery
DPW, Bldg. 777
Fort Bliss, TX 79916
RE: ASBESTOS SURVEY REPORT
Building 2447
Fort Bliss, TX 79916
Dear Mr. Wilson,
ENCON International, Inc., (ENCON) has submitted for your review the attached Asbestos
Survey Report. This Asbestos Survey was conducted in accordance with Asbestos National
Emissions Standards for Hazardous Air Pollutants (NESHAP): 40 CFR Part 61, Subpart M.
Sampling protocols were performed in accordance with the Texas Asbestos Health Protection
Rules (TAHPR).
This Asbestos Survey was properly performed by ENCON DSHS licensed personnel. ENCON’s
personnel have been trained and are in compliance with Texas Department of State Health
Services (DSHS) regulations. If you have any questions regarding this Asbestos Survey, please
feel free to contact us at your convenience.
Sincerely,
Alex Woelper, P.E.
Program Manager
Attachments:
Asbestos Survey Report
Asbestos Drawings
Photo Log
Laboratory Documentation
E N C O N INTERNATIONAL, INC.
-- 3 of 40 --
Asbestos Survey Report ENCON International, Inc.
Ft. Bliss, Bldg. 2447 Project No. 103-08-094
Page 1
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740
ASBESTOS SURVEY REPORT
Ft. Bliss, Bldg. 2447
SUMMARY
ENCON International, Inc. (ENCON) personnel performed an Asbestos Inspection of a structure
designated as “Building 2447” on Fort Bliss, Texas. The following are the field sample
collection and analysis results for this inspection. The inspection was conducted to ensure
compliance with NESHAP – 40 CFR Part 61, Subpart M, which states that “prior to the
commencement of the demolition or renovation, thoroughly inspect the affected facility or part
of the facility where the demolition or renovation operation(s) will occur for the presence of
asbestos, including Category I and Category II non-friable ACM. ”
The sample collection and subsequent laboratory analytical results indicated that asbestos
was not identified in the sampled building materials.
INTRODUCTION
This Asbestos Survey was performed by Mr. David Morales on June 12th, 2008. This Asbestos
Survey was conducted in accordance with Asbestos National Emissions Standards for Hazardous
Air Pollutants (NESHAP): 40 CFR Part 61, Subpart M. Sampling protocols were performed in
accordance with the Texas Asbestos Health Protection Rules (TAHPR). Building 2447 was to
undergo renovations and was visually inspected and it was determined that the suspect asbestos-
containing materials could be divided into thirty (30) homogeneous areas, including the
following: rubberized flooring mastic (3 types), cove base mastic (9 types), textured
drywall/joint compound (8 types), 12” x 12” floor tile & mastic (3 types), carpet mastic (4
types), 2’ x 4’ ceiling panels (2 types), and textured stucco.
DESCRIPTION
Building 2447 was being used as military personnel housing on Fort Bliss, Texas. The building
occupied approximately 38,000 SF. The building was a three-story structure constructed with
-- 4 of 40 --
Asbestos Survey Report ENCON International, Inc.
Ft. Bliss, Bldg. 2447 Project No. 103-08-094
Page 2
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740
CMU walls on a concrete foundation. The interior was partitioned with drywall walls. The floor
was covered with floor tile and carpeting. At the time this Asbestos Survey was performed, the
date of construction was not known.
SAMPLING METHODOLOGY
A visual inspection of the building was conducted to develop a sampling plan. This included
determining sample collection points, homogeneous materials and areas. Friability was assessed
by manually manipulating the suspect asbestos materials utilizing hand pressure to determine if
the materials, when dry, can be crumbled, pulverized, or reduced to powder. Thirty (30)
homogeneous areas were established and at least three (3) samples were collected from each
area. Areas that have suspect asbestos-containing surfacing, thermal systems insulation, or
miscellaneous materials are to be considered homogeneous. These samples were each uniquely
and individuall…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 236220)
Matsushima JASDF Base Storage Shelter
DEPT OF DEFENSE · Sources Sought · due August 7, 2026
Repair Concrete Base-wide, 126 ARW, Scott AFB
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due August 14, 2026
Z1DA--| SOL| NRM| 646-21-101 UD SPS AHU & RO Upgrade Construction (VA-26-00036217)
VETERANS AFFAIRS, DEPARTMENT OF · Solicitation · due August 27, 2026
Department of Treasury 5th Floor Renovation
TREASURY, DEPARTMENT OF THE · Solicitation · due August 13, 2026
NAF Outdoor Recreation/Equipment Rental Center, Kadena Air Base, Okinawa, Japan
DEPT OF DEFENSE · Solicitation · due July 24, 2026
Z--Expansion of the PIFSC Glider Lab, JBPHH
COMMERCE, DEPARTMENT OF · Solicitation · due August 7, 2026