HVAC Preventative Maintenance for Fort Hall Service Unit, Fort Hall, ID

HEALTH AND HUMAN SERVICES, DEPARTMENT OF

Notice type
Sources Sought
Solicitation #
REQT-IHS-2026-00357
NAICS
238220
PSC
J041
Set-aside
No Set aside used
Posted
November 19, 2026
Response due
December 4, 2026
Place of performance
Fort Hall, ID

What this opportunity is

The Department of Health and Human Services is seeking vendors for preventative maintenance services on the HVAC system, chiller, and controls at the Fort Hall Service Unit in Fort Hall, ID. This opportunity is open to all business types, including native small businesses, with a focus on compliance with ASHRAE standards for healthcare ventilation. As a Sources Sought Notice, this is not a solicitation for bids but rather a request for information to gauge vendor capabilities, so interested parties should track this opportunity for future solicitation announcements.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

1. Title Preventative maintenance service agreement for the HVAC system, Chiller and Controls at the Fort Hall Service Unit (FHSU), Fort Hall, ID. 2. Background The Fort Hall Service Unit is accredited by the Accreditation Association for Ambulatory Health Care (AAAHC). The FHSU continually demonstrates a clinic-wide effort to maintain the highest standards of care and to improve the health status of their patients. FHSU specializes in the promotion of comprehensive family healthy for federally recognized American Indian and Alaska Native people and their descendants. The clinic requires preventative maintenance of the HVAC system to optimize facility operations and energy efficiency without interruptions to patient care. 3. Scope Perform preventative maintenance services on the HVAC system, Chiller and Controls to ensure the facility is ventilated in accordance with the most current version of ASHRAE 170 – Ventilation of Health Care Facilities, and ASHRAE 62.1 – Ventilation for Acceptable Indoor Air Quality. 4. Specific Tasks or Specifications Preventative Maintenance Tasks: At a minimum, the following task shall be completed unless the manufacture’s recommendations require additional task or intervals. Air Handlers Units, Mixed Air, 25 HP (QTY=1), 3/4 HP (QTY=3). Return Air Fan, 10 HP (QTY=1). Comprehensive – Minimum 1 per yearCheck with appropriate customer representative for operational deficiencies Visually inspect damper(s) Check condition of pulleys and belts Check for proper fan operation Check condition of coils Check condition of filters Record temperatures and pressures (if applicable) Check for unusual noise and vibration Check for deterioration of gaskets and seals Check overall condition of unit Visually inspect for fluid leaks of coils and connecting piping Check starter/contactor Check and tighten electrical connections Check damper operation and lubricate as required Visually check control valve(s) Lubricate blower and motor bearings Clean condensate pan and clear drain line Check condition of blower assembly Remove and dispose of any debris from any maintenance activity Document tasks performed during visit and report any observations to appropriate customer representative Operational – Minimum 1 per year Check with appropriate customer representative for operational deficiencies Inspect motor mounting isolators Check for integrity of cabinet hardware Visually inspect damper(s) Verify damper operation Check condition of pulleys and belts Check for proper fan operation Check condition of coils Check condition of filters Record temperatures and pressures (if applicable) Check condensate drain Visually inspect electrical connections Check for unusual noise and vibration Check overall condition of unit Visually inspect for fluid leaks of coils and connecting piping Document tasks performed during visit and report any observations to appropriate customer representative Belt Change – As needed Check with appropriate customer representative for operational deficiencies Perform belt change procedures Remove and dispose of any debris from any maintenance activity Document tasks performed during visit and report any observations to appropriate customer representative. Coil Cleaning – Minimum 1 per year Check with appropriate customer representative for operational deficiencies Clean condensate drain (if necessary) Spray coil(s) with chemical solution Rinse coil(s) thoroughly with water Remove and dispose of any debris from any maintenance activity Document tasks performed during visit and report any observations to appropriate customer representative Exhaust Fans, EF ½ HP (QTY=1), EF ¼ HP (QTY=3), IEF ¼ HP (QTY=1), BEF ¼ HP (QTY=1) Comprehensive – Minimum 1 per yearCheck with appropriate customer representative for operational deficiencies Check condition of pulleys and belts Check for proper fan operation Record temperatures and pressures (if applicable) Check for unusual noise and vibration Check overall condition of unit Check and tighten electrical connections Check condition of blower assembly Remove and dispose of any debris from any maintenance activity Document tasks performed during visit and report any observations to appropriate customer representative Operational – Minimum 1 per year Check with appropriate customer representative for operational deficiencies Check condition of pulleys and belts Record temperatures and pressures (if applicable) Visually inspect electrical connections Check for unusual noise and vibration Check overall condition of unit Document tasks performed during visit and report any observations to appropriate customer representative Belt Change – As needed Check with appropriate customer representative for operational deficiencies Perform belt change procedures Remove and dispose of any debris from any maintenance activity Document tasks performed during visit and report any observations to appropriate customer representative. Boilers, Gas-Fired, 850 Sonic Condensing (QTY=2) Comprehensive – Minimum 1 per yearCheck with appropriate customer representative for operational deficiencies Inspect burner/oil pump contactors for wear Check and tighten electrical connections Check for proper gas supply pressure Check oil pump for proper operation Check and clean pilot assembly Clean combustion fan wheel Visually inspect combustion chamber, draft diverter and flue for accumulation of soot - clean as needed Check burner for proper sequence of operation Check operating controls Check all safety controls Lift relief valve to ensure proper operation Check boiler relief valves for leakage Check combustion blower motor operation and lubricate as needed Check for proper operation of oil preheaters (if applicable) Check factory supplied oil and gas piping and components for leakage Drain boiler, open hand hole covers and clean as needed (if …

Source: SAM.gov, as posted. Verify the current solicitation before responding.