Scissor Lift Repair

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
M0068126Q0054
NAICS
811310
PSC
J039
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 26, 2026
Response due
July 1, 2026
Place of performance
Oceanside, CA

What this opportunity is

The Department of Defense is seeking scissor lift repair services, classified under NAICS 811310 and PSC J039. This procurement is set aside for total small business, making it suitable for small businesses. As a sources sought notice, this is a preliminary step to identify potential vendors, and businesses should track this opportunity rather than submitting a bid at this time.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

STATEMENT OF WORK SCISSOR LIFT REPAIR Background MCB Camp Pendleton utilizes horizontal carousels to store thousands of Marine Corps equipment repair parts. The carousels are accessed multiple times daily utilizing scissor lifts manufactured by Autoquip - see the attached. The equipment maintenance contractor has indicated that one lift either needs to be repaired or replaced as soon as possible. Objectives To repair a scissor lift. Scope To provide and install the required parts needed to return the lift to a fully operational status. Tasks Task Number Work Milestones Projected Completion Date 2.1 Site Visit TBD 2.2 Furnish materials TBD 2.3 Installation TBD 2.4 The TPOC will inspect the job when completed TBD 1. Upon award, the contractor is to provide a repair start date to the TPOC once the contractor has received the required repair parts. 2. Place Of Performance: The job site location is aboard MCB Camp Pendleton, Ca in building 2251. 2.1 - Site Visit: Contractors are to attend a site visit to confirm required repairs 2.2 - Furnish Materials: The contractor will provide the materials required as indicated below: Leg assembly and hydraulics (base frame, cylinders, hosing) 2.3 - Installation: The contractor is to repair the scissor lift. Contractor Responsibilities: DISTRIBUTION: DoW COMMUNITY ONLY -- 1 of 5 -- Generic SOW Temp'ate Remove damaged parts and place them outside of the building 2251 Install the new parts Test the lift to ensure proper operation Government Responsibilities: Provide access to the building Provide access to available power Remove the damaged parts from the job site 2.4 - Completed Job Inspection: The contract does not contain a Quality Assurance Survellance Plan (QASP); however, the TPOC will inspect the job for quality upon completion. Quality will be measured in accordance with the following: Description Of Work Contractors quoted materials at the time of the solicitation 3. Government Tecliiiical Point Of Contact: The Contracting Officer will designate a Government Technical Point Of Contact ( TPOC) during the term of the contract. The TPOC will provide assistance in identifying and resolving problems and provide technical clarification and assistance in support of the contract. The TPOC DOES NOT have the authority to make changes and/or give direction under this contract. The only person that can authorize the above is the Contracting Office from the Regional Contracting Office MCI- WEST, Camp Pendleton, Ca. Steve Elggren 760 725-3172 steven.e1ggren@usmc.mil 4. Base Access DISTRtBUTION: DoW COMMUNITY ONLY -- 2 of 5 -- rn b --.-. I - - N I -- I 9 I. MATERIALS: 1/4' Thick Smooth Flat Steel with Fine Oxide Grit Finish LiFTING CAPACIEY: 2,000 lbs, 1,000 lb. Side load, and 500 lb. End load TRAVEL: 72 - LOWERED HEIGHT: B, Approximately 4" of toe clearance when lift in lowered posion rs F' ' S j 1IJ -- 3 of 5 -- IISXA1;4I1LIi - - ' ''-' '"I- 'I" - ..: " , , : "' _ S - I- .i. - - I S - 5-. 5 I - - -- III I S.,-, - - - - I. - - S.. :. -- IS I. " II S - S - - - - S -e . - - S - - ; 5 " - S S - S " 51.15 II I I 5" I S - - I - S - "SIS - - - "'.I .! LLt S 'S"S ';A:j!; ;\ "S "_O -- 4 of 5 -- E STOP CHAIN ACROSS ACCESS OPENING 14 FRONT V8EW Ii.1I111LI ANYWHERE REAR VIEW (FROM CAROUSEL SftDE) ON CENTER RAILING 14-0" TREAR VEW 4" - rLt"L UP/DOWH I0 SWTCH & ELECTRICAL 77.5" OUTLETS ANYWHERE ON HAND RAIL RGHT VIEW 3cIearPf- ( POWER SOURCE 0> ii(iIYkI1 LELECTRICAL OUTLET MOU NTED ON KICK PLATE. ADDITIONAL POWER STRIP TO BE ADDED. FRONT VIEW 6-0" H 6-0" H 6-0" H in TET 48" 48' I. .I IIIi*TiI q4" 88.5" 31.5" 13" -- 5 of 5 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 811310)