USCG TRACEN PETALUMA SIEMENS FIRE ALARM SYSTEM REPAIR

HOMELAND SECURITY, DEPARTMENT OF

Notice type
Solicitation
Solicitation #
61200PR270005532
NAICS
561621
PSC
J063
Set-aside
Small Business Set Aside - Total
Posted
November 13, 2026
Response due
November 23, 2026
Place of performance
Petaluma, CA

What this opportunity is

The Department of Homeland Security is soliciting small businesses for the repair of a Siemens fire alarm system at the USCG TRACEN Petaluma in California, under NAICS code 561621. This opportunity is a total small business set-aside, making it suitable for small contractors with a size standard of $25 million. Interested vendors should note that full funding is not currently available, and offers must be submitted by the specified deadline, with a site visit scheduled for November 18, 2026.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

PR # 61200PR2700055532 STATEMENT OF WORK LAST UPDATED: 11/13/2026 STATEMENT OF WORK (SOW) FOR Steadman Fire Alarm Panel Repair 1.0 GENERAL 1.1 BACKGROUND U.S. Coast Guard (USCG) Training Center (TRACEN) Petaluma located at 599 Tomales Road Petaluma; CA 94952 is the Coast Guard’s largest West Coast Training Center. Our graduates are the latest chefs, medics, storekeepers, yeoman, information systems technicians, electronics technicians, operations specialists, and aviation survival technicians (AST). We are also home to the Coast Guard Leadership Development Center’s Chief Petty Officer Academy. 1.2 SCOPE The requirement of this contract is for the contractor to furnish all labor, qualified personnel, tools, materials, equipment, supplies, services, and other items necessary to troubleshoot and correct an ongoing fire-alarm ground-fault condition on the Siemens XLS FireFinder at USCG TRACEN Petaluma. 1.3 OBJECTIVE The Contractor shall furnish all supervision, qualified personnel, diagnostic equipment, tools, materials, transportation, and incidentals required to troubleshoot, trace, repair, and fully restore the affected fire-alarm field circuit to normal operating condition, eliminating the active ground- fault condition on the Siemens FireFinder-XLS system at the U.S. Coast Guard (USCG) Training Center (TRACEN) Petaluma, located at 599 Tomales Road, Petaluma, CA 94952. 1.4 APPLICABLE DOCUMENTS 1.4.1 Reference Documents The following documents may be helpful to the Contractor in performing the work described in this document: • NFPA 72 (National Fire Alarm and Signaling Code) • NFPA 70 (National Electrical Code - NEC) 2.0 SPECIFIC REQUIREMENTS/TASKS 2.1 TASK ONE. FIRE-ALARM PANEL TROUBLESHOOTING AND DIAGNOSTICS • Diagnose and correct the ongoing fire-alarm ground fault panel condition on the Siemens XLS FireFinder. • Inspect the fire-alarm control panel, associated power supplies, batteries, modules, wiring terminations, and connected field circuits as necessary to identify the source of the fault condition. 2.2 TASK TWO. FIELD-CIRCUIT TESTING AND REPAIR • Trace, test, and isolate the affected fire-alarm field wiring and devices to identify the location and cause of the issue. • Repair, replace, reconnect, or re-terminate defective field wiring, connections, or related components necessary to restore the affected circuit to proper operation. -- 1 of 5 -- PR # 61200PR2700055532 STATEMENT OF WORK LAST UPDATED: 11/13/2026 • Furnish sufficient compatible fire-alarm wiring and associated repair materials to complete corrective repairs during the service visit if the fault is confirmed in the field wiring. 2.3 TASK THREE. FIRE-ALARM PANEL REPAIR AND RESTORATION • Repair or replace defective fire-alarm panel components, modules, terminals, power- supply components, or related equipment as required to eliminate the identified trouble condition. • Restore the fire-alarm control panel and affected circuit to normal operating condition upon completion of repairs. • Perform all required panel resets, functional checks, and verification testing following repair activities. 2.4 TASK FOUR. SYSTEM MONITORING AND COORDINATION • Maintain appropriate monitoring of the fire-alarm control panel throughout troubleshooting and repair activities to minimize disruption to the facility fire-alarm system. • Coordinate all required alarm impairments, testing activities, resets, and restoration actions with designated USCG TRACEN Petaluma personnel. • Immediately notify the Government representative of any condition that cannot be corrected during the service visit or that requires additional materials, labor, or follow-on repairs. 2.5 TASK FIVE. FUNCTIONAL TESTING AND DOCUMENTATION • Verify that the repaired fire-alarm panel and affected field circuit are free of the identified ground-fault condition and operate normally upon completion of repairs. • Conduct functional testing of repaired components and associated circuits to confirm proper system operation. • Provide a written service report identifying the reported condition, troubleshooting performed, findings, repairs completed, materials used, test results, and any recommended follow-on actions. 2.6 TASK SIX. FINAL SYSTEM STATUS AND CLOSEOUT • Return the fire-alarm control panel and affected systems to normal operating status at the conclusion of the service visit. • Ensure all work areas are cleaned and all debris, removed components, packaging, and unused materials are removed from Government property. • Provide the Government representative with final notification that the system has been restored or document any remaining deficiencies requiring additional corrective action. 2.7 TASK SEVEN. WARRANTY • Contractor shall include a one-year warranty for all work performed. 3.0 CONTRACTOR PERSONNEL 3.1 QUALIFIED PERSONNEL The Contractor shall provide qualified personnel holding a NICET Level 2 certification or C10 certification. -- 2 of 5 -- PR # 61200PR2700055532 STATEMENT OF WORK LAST UPDATED: 11/13/2026 3.1.1 NICET Level 2 Certification Requirements: • A minimum of 2 years of fire detection and signaling systems experience. • Must include at least 12 months of fire alarm systems experience (including alarm and detection, notification, sprinkler monitoring, and interfaces/controls for agent releasing • suppression systems) in roles such as installation, inspection, testing, commissioning, technical system estimating/sales, or plan preparation/maintenance. 3.1.2 C-10 Electrical Contractor License (California): • Requires 4 years of journeyman-level experience in electrical work within the past 10 years, verifiable through documentation. • C-10 holders can legally perform low-voltage systems work (equivalent to C-7 work), residential/commercial/industrial wiring, solar PV systems, EV charging stations, panel upgrades, and generator installations. • Limitations: Cannot perform fire protection system installation/servicing that requir…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 561621