What this opportunity is
The Department of Defense is seeking services from an ABS-approved firm to conduct ultrasonic gauging on the USNS Kaiser, specifically for hull, bulkheads, deck plating, and piping, as part of the Enhanced Survey Program's Special Hull Survey No. 8. This opportunity is open to all business types, as there is no set-aside. Interested vendors should note that this is a combined synopsis/solicitation, which means they will need to track the solicitation closely for submission requirements and deadlines.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
USNS KAISER
(T-AO 187)
HULL AND STRUCTURAL N4044327Q0003
ITEM NO. 0100 CATEGORY "A" 2026-04-29
PWS ROPING AND ULTRASONIC GAUGING
SERVICES ESP HULL SPECIAL SURVEY 8
C. Crawford
WI-0100, Page - 1
1.0 ABSTRACT:
Provide the services of an ABS approved ESP Hull Gauging firm to take and record
ultrasonic thickness readings on ship's hull, bulkheads, deck plating, scantlings,
piping, and in other areas throughout the ship as required by the MSCREP, USCG,
and ABS Surveyor. The requirements of the ABS Special Hull Survey No.8 for
Single Hull Tankers in the Enhanced Survey Program shall form the basis for this
item.
2.0 REFERENCES/ENCLOSURES:
2.1. NAVSEA Dwg No. 6630531 - General Arrangement Outboard Profile.
2.2. NAVSEA Dwg No. 5903963 - General Arrangement Inboard Profile.
2.3. NAVSEA Dwg No. 5903954 - Scantling Plan.
2.4. NAVSEA Dwg. No. 5903954 - Scantling Sections.
2.5. NAVSEA Dwg No. 5751075 - Shell Expansion Scantlings.
2.6. NAVSEA Dwg. No. 8388193 - General Arrangement Tanks and Flats, Aft Fr. 60.
2.7. NAVSEA Dwg. No. 801-5904296 - Capacity Plan.
2.8. NAVSEA Dwg. No. 631-6240525, MSC “Paint Schedule”.
2.9. ABS Rules for Building and Classing Steel Vessels, Part 7, Rule Requirements for
Survey After Construction Part 7, Chapter 3 Section 2. Tanker ESP (requirements
for Special Hull Survey No. 8).
2.10. ESP PROGRAM Special Hull Survey No. 8 – USNS HENRY J. KAISER
(T-AO 187).
3.0 ITEM LOCATION/DESCRIPTION:
3.1. Location/Quantity:
3.1.1. Location: Various locations throughout the vessel.
3.1.2. Quantity: 35,000 UT readings.
3.2. Item Description/Manufacturer's Data: None
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES/INFO:
4.1. GOVERNMENT FURNISHED EQUIPMENT: None.
4.2. GOVERNMENT FURNISHED MATERIAL: None.
4.3. GOVERNMENT FURNISHED SERVICES: None.
4.4. GOVERNMENT FURNISHED INFO: None.
-- 1 of 7 --
USNS KAISER
(T-AO 187)
HULL AND STRUCTURAL N4044327Q0003
ITEM NO. 0100 CATEGORY "A" 2026-04-29
PWS ROPING AND ULTRASONIC GAUGING
SERVICES ESP HULL SPECIAL SURVEY 8
C. Crawford
WI-0100, Page - 2
5.0 NOTES:
5.1. The contractor and all subcontractors, regardless of tier must consult the General
Technical Requirements (GTR) to determine applicability to this work item. In
performance of this work item, the contractor and all subcontractors must comply
with all applicable GTRs.
5.2. There will be two (2) Locations and POP:
5.2.1. Location: San Diego, CA. 25 November 2026 – 09 December 2026.
5.2.2. Location two: Portland, OR. Vigor Marine shipyard: Dry Dock Gauging, 7
consecutive Days Onsite during the Dry-Docking period from Tue 1/5/27
to Fri 2/19/27. No roping access services required at location two.
5.3. Detailed Unit Structural Drawings can be provided by MSC Tech Library
upon request.
5.4. Cleaning of cargo and ballast tanks will be accomplished by Ship’s Force
(in San Diego).
6.0 QUALITY ASSURANCE REQUIREMENTS: Refer to Paragraph 7.0
7.0 STATEMENT OF WORK:
7.1. Contractor shall provide a certified marine chemist to gas free thirty-six
(36) cargo and ballast tanks, throughout the period of performances for tank
surveys and thickness gauging including overtime hours, weekends and holidays.
Contractor shall provide a qualified competent person to perform air quality
testing of the tanks atmospheres throughout the day as required after the initial
gas free of the tanks has been certified by the certified marine chemist.
7.2. Provide all labor, materials and equipment to satisfy the requirements of
ABS Special Hull Survey No. 8 for Non-Double Hull Tankers in the Enhanced
Survey Program (ESP) and to obtain and record 35,000 ultrasonic thickness
readings using references 2.1 through 2.10 as guidance. This is to be worked in-
conjunction with ABS close-up survey of the tanks and voids.
7.3. The thickness measurements shall be carried out by an ABS recognized
ESP Hull Gauging Firm according to the principles stated in Section 7-A-5 of
reference 2.10. The qualifications of the ABS approved ESP Hull Gauging Firm
shall be provided to the MSCREP prior to the start of the audio gauging.
7.4. The contractor is to provide a unit price per shot up to a maximum of
35,000 Shots. Number of shots will be determined by quantity required by ABS.
The unit price is to be used for decreasing the scope of the item as it relates to the
number of shots required by ABS.
7.5. The contractor shall employ rope access personnel for the Ultrasonic
-- 2 of 7 --
USNS KAISER
(T-AO 187)
HULL AND STRUCTURAL N4044327Q0003
ITEM NO. 0100 CATEGORY "A" 2026-04-29
PWS ROPING AND ULTRASONIC GAUGING
SERVICES ESP HULL SPECIAL SURVEY 8
C. Crawford
WI-0100, Page - 3
Technician to direct probe (transducer) placement for the purpose of obtaining
material thickness and/or positioning of a video feed for the attending Surveyor or
the Level II Technician to assess the condition.
7.5.1. Rope Access:
7.5.1.1. Rope Access certified contractor personnel shall perform all rope
access rigging, climbing and Rope Access in accordance with
their procedure documents and regulatory requirements.
7.5.1.2. Rope access personnel shall be fitted with a GoPro camera system
mounted to their approved hard hat.
7.5.1.3. Rope Access personnel shall be fitted with Rope Access contractor
provided communications.
7.5.1.4. Ultrasonic Level II UT Technician shall calibrate the ultrasonic unit
in accordance with the applicable procedure or Classification
requirements with contractor provided transducer, coax cable,
ultrasonic unit, and calibration standard.
7.5.1.5. Rope Access personnel shall be instructed by the Level II UT
Technician and/or Class Surveyor which specific structure
requires access for UTT gauging and/or visual close-up
inspection and shall be briefed on the general visual inspection
to be covered while live streaming to the Level II UT technician
and/or Class Surveyor video monitor.
7.5.1.6. Rope Access personnel shall perform final equipment check
including video, communications, lighting, and Rope Access
rigging.
7.5.1.7. Rope Access personnel shall …
Source: SAM.gov, as posted. Verify the current solicitation before responding.