Skip to content

Open for responses

USNS KAISER (T-187 Ultrasonic Gauging Hull Special Survey 8)

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
N4044327Q0003
NAICS
541380
PSC
H219
Set-aside
No Set aside used
Posted
November 13, 2026
Response due
November 18, 2026
Place of performance
San Diego, CA

What this opportunity is

The Department of Defense is seeking services from an ABS-approved firm to conduct ultrasonic gauging on the USNS Kaiser, specifically for hull, bulkheads, deck plating, and piping, as part of the Enhanced Survey Program's Special Hull Survey No. 8. This opportunity is open to all business types, as there is no set-aside. Interested vendors should note that this is a combined synopsis/solicitation, which means they will need to track the solicitation closely for submission requirements and deadlines.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

USNS KAISER (T-AO 187) HULL AND STRUCTURAL N4044327Q0003 ITEM NO. 0100 CATEGORY "A" 2026-04-29 PWS ROPING AND ULTRASONIC GAUGING SERVICES ESP HULL SPECIAL SURVEY 8 C. Crawford WI-0100, Page - 1 1.0 ABSTRACT: Provide the services of an ABS approved ESP Hull Gauging firm to take and record ultrasonic thickness readings on ship's hull, bulkheads, deck plating, scantlings, piping, and in other areas throughout the ship as required by the MSCREP, USCG, and ABS Surveyor. The requirements of the ABS Special Hull Survey No.8 for Single Hull Tankers in the Enhanced Survey Program shall form the basis for this item. 2.0 REFERENCES/ENCLOSURES: 2.1. NAVSEA Dwg No. 6630531 - General Arrangement Outboard Profile. 2.2. NAVSEA Dwg No. 5903963 - General Arrangement Inboard Profile. 2.3. NAVSEA Dwg No. 5903954 - Scantling Plan. 2.4. NAVSEA Dwg. No. 5903954 - Scantling Sections. 2.5. NAVSEA Dwg No. 5751075 - Shell Expansion Scantlings. 2.6. NAVSEA Dwg. No. 8388193 - General Arrangement Tanks and Flats, Aft Fr. 60. 2.7. NAVSEA Dwg. No. 801-5904296 - Capacity Plan. 2.8. NAVSEA Dwg. No. 631-6240525, MSC “Paint Schedule”. 2.9. ABS Rules for Building and Classing Steel Vessels, Part 7, Rule Requirements for Survey After Construction Part 7, Chapter 3 Section 2. Tanker ESP (requirements for Special Hull Survey No. 8). 2.10. ESP PROGRAM Special Hull Survey No. 8 – USNS HENRY J. KAISER (T-AO 187). 3.0 ITEM LOCATION/DESCRIPTION: 3.1. Location/Quantity: 3.1.1. Location: Various locations throughout the vessel. 3.1.2. Quantity: 35,000 UT readings. 3.2. Item Description/Manufacturer's Data: None 4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES/INFO: 4.1. GOVERNMENT FURNISHED EQUIPMENT: None. 4.2. GOVERNMENT FURNISHED MATERIAL: None. 4.3. GOVERNMENT FURNISHED SERVICES: None. 4.4. GOVERNMENT FURNISHED INFO: None. -- 1 of 7 -- USNS KAISER (T-AO 187) HULL AND STRUCTURAL N4044327Q0003 ITEM NO. 0100 CATEGORY "A" 2026-04-29 PWS ROPING AND ULTRASONIC GAUGING SERVICES ESP HULL SPECIAL SURVEY 8 C. Crawford WI-0100, Page - 2 5.0 NOTES: 5.1. The contractor and all subcontractors, regardless of tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors must comply with all applicable GTRs. 5.2. There will be two (2) Locations and POP: 5.2.1. Location: San Diego, CA. 25 November 2026 – 09 December 2026. 5.2.2. Location two: Portland, OR. Vigor Marine shipyard: Dry Dock Gauging, 7 consecutive Days Onsite during the Dry-Docking period from Tue 1/5/27 to Fri 2/19/27. No roping access services required at location two. 5.3. Detailed Unit Structural Drawings can be provided by MSC Tech Library upon request. 5.4. Cleaning of cargo and ballast tanks will be accomplished by Ship’s Force (in San Diego). 6.0 QUALITY ASSURANCE REQUIREMENTS: Refer to Paragraph 7.0 7.0 STATEMENT OF WORK: 7.1. Contractor shall provide a certified marine chemist to gas free thirty-six (36) cargo and ballast tanks, throughout the period of performances for tank surveys and thickness gauging including overtime hours, weekends and holidays. Contractor shall provide a qualified competent person to perform air quality testing of the tanks atmospheres throughout the day as required after the initial gas free of the tanks has been certified by the certified marine chemist. 7.2. Provide all labor, materials and equipment to satisfy the requirements of ABS Special Hull Survey No. 8 for Non-Double Hull Tankers in the Enhanced Survey Program (ESP) and to obtain and record 35,000 ultrasonic thickness readings using references 2.1 through 2.10 as guidance. This is to be worked in- conjunction with ABS close-up survey of the tanks and voids. 7.3. The thickness measurements shall be carried out by an ABS recognized ESP Hull Gauging Firm according to the principles stated in Section 7-A-5 of reference 2.10. The qualifications of the ABS approved ESP Hull Gauging Firm shall be provided to the MSCREP prior to the start of the audio gauging. 7.4. The contractor is to provide a unit price per shot up to a maximum of 35,000 Shots. Number of shots will be determined by quantity required by ABS. The unit price is to be used for decreasing the scope of the item as it relates to the number of shots required by ABS. 7.5. The contractor shall employ rope access personnel for the Ultrasonic -- 2 of 7 -- USNS KAISER (T-AO 187) HULL AND STRUCTURAL N4044327Q0003 ITEM NO. 0100 CATEGORY "A" 2026-04-29 PWS ROPING AND ULTRASONIC GAUGING SERVICES ESP HULL SPECIAL SURVEY 8 C. Crawford WI-0100, Page - 3 Technician to direct probe (transducer) placement for the purpose of obtaining material thickness and/or positioning of a video feed for the attending Surveyor or the Level II Technician to assess the condition. 7.5.1. Rope Access: 7.5.1.1. Rope Access certified contractor personnel shall perform all rope access rigging, climbing and Rope Access in accordance with their procedure documents and regulatory requirements. 7.5.1.2. Rope access personnel shall be fitted with a GoPro camera system mounted to their approved hard hat. 7.5.1.3. Rope Access personnel shall be fitted with Rope Access contractor provided communications. 7.5.1.4. Ultrasonic Level II UT Technician shall calibrate the ultrasonic unit in accordance with the applicable procedure or Classification requirements with contractor provided transducer, coax cable, ultrasonic unit, and calibration standard. 7.5.1.5. Rope Access personnel shall be instructed by the Level II UT Technician and/or Class Surveyor which specific structure requires access for UTT gauging and/or visual close-up inspection and shall be briefed on the general visual inspection to be covered while live streaming to the Level II UT technician and/or Class Surveyor video monitor. 7.5.1.6. Rope Access personnel shall perform final equipment check including video, communications, lighting, and Rope Access rigging. 7.5.1.7. Rope Access personnel shall …

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 541380