Skip to content

Open for responses

Breathing Air Systems Services for Fire Emergency Services at EAFB and P42

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
FA930127Q0003
NAICS
811310
PSC
J042
Set-aside
No Set aside used
Posted
October 19, 2026
Response due
November 18, 2026
Place of performance
Edwards, CA

What this opportunity is

The Department of Defense is seeking commercial services for preventive maintenance, unscheduled repairs, and certified air quality sampling of high-pressure breathing air compressor systems at Edwards AFB and Air Force Plant 42 in California. This opportunity is open to all businesses, as there is no set-aside, and it falls under NAICS 811310. Interested contractors should note that this is a combined synopsis/solicitation, meaning they must track the notice closely for submission deadlines and requirements, as no separate solicitation will be issued.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Statement of Work For Breathing Air Compressor Systems Preventive Maintenance, Unscheduled Repair, and Certified Air Sampling Edwards AFB Fire Emergency Services and Air Force Plant 42 Fire Department Edwards AFB, CA 19 October 2026 -- 1 of 9 -- Page | 2 1. SCOPE: This Statement of Work (SOW) provides for and outlines the requirements for conducting annual maintenance, unscheduled repairs, and air samples on Bauer (TCOM- 26 and DOTR26-WRAF) and Stallion (Centaur) compressor systems utilized by the Edwards Air Force Base Fire Emergency Services and Plant 42 Fire Department. The Contractor shall furnish all supervision, equipment, tools, labor, materials, and supplies necessary to perform the required work. The work shall be performed in accordance with this SOW. 2. LOCATION and SITE VERIFICATION: The Contractor shall conduct work at Edwards AFB Fire Stations 1 and 4 and Plant 42 Fire Station 1. All required work will be performed at these locations by the Contractor. 3. DESCRIPTION OF WORK: The intent of this effort is to have the department’s air compressor systems maintained and repaired in accordance with manufacturer’s recommendations. Annual Maintenance Perform the following annual maintenance on the Centaur (Stallion Air Inc): replace oil and inspect oil pressure; inspect air pressure gauges; calibrate CO monitor/moisture indicator; change purification filters and O-rings; service auto-drain with a minor or major service kit; check auto drain for proper dump time; lubricate motor/engine; inspect on-off button/emergency stop; inspect fill whips; inspect muffler, reservoir and drain; inspect regulators; inspect doors, panels, and frame; inspect piping fittings and monitor for air leaks; ensure head bolts are at proper torque; inspect and clean cooling fans; service final separator and replace O-rings; clean compressor; inspect compressor and fill system for air leaks; inspect and replace air/intake filter; inspect and clean compressor coolers; inspect drive belts; check and record inter-stage pressure readings; and inspect door opening air system and conduct air sampling in compliance with NFPA 1989. Perform the following maintenance on the TCOM-26 (Bauer Compressors): replace oil and inspect oil pressure; inspect air pressure gauges; calibrate CO monitor/moisture indicator; change purification filters and O-rings; service auto-drain with a minor or major service kit; check auto drain for proper dump time; lubricate motor/engine; inspect on-off button/emergency stop; inspect fill whips; inspect muffler, reservoir and drain; inspect regulators; inspect doors, panels, and frame; inspect piping fittings and monitor for air leaks; ensure head bolts are at proper torque; inspect and clean cooling fans; service final separator and replace O-rings; clean compressor; inspect compressor and fill system for air leaks; inspect and replace air/intake filter; inspect and clean compressor coolers; inspect drive belts; check and record inter-stage pressure readings; and inspect door opening air system and conduct air sampling in compliance with NFPA 1989. Perform the following maintenance on the DOTR26-WRAF (Bauer Compressors): inspect, service, collect samples for testing, and perform maintenance and repairs of the complete self-contained breathing air recharge system; including the diesel components. All air samples must be tested by an approved company. All maintenance and repair actions shall be -- 2 of 9 -- Page | 3 in accordance with the most current edition of 29 CFR 1910, Occupational Safety and Health Standards and the National Fire Protection Association (NFPA) Standards, 1404 and 1500; Compressed Gas Association Pamphlet S-1.1-1963/1965. S-1.2-1963 and manufacturer’s recommendations and service bulletins. Components requiring service include. but are not limited to air purification systems, compressors, cascade systems, lines and fittings, alarms, dehumidifier, air bottle refill stations, and all monitoring devices. The contractor shall also ensure the requirements of Occupational Safety and Health Administration (OSHA) 1910.134 standard for Respiratory Protection and applicable Federal regulations are met. Breathing Air Samples Quarterly air samples shall be performed in compliance with NFPA 1989 and OSHA 1910.134. Unscheduled Repairs and Emergency Services The Contractor shall provide diagnostic, troubleshooting, and unscheduled repair services for the Centaur (Stallion Air Inc), Bauer (TCOM-26), and Bauer Mobile Breathing Air Compressor (DOTR26-WRAF) systems on an as-needed basis. This agreement covers routine and emergency repairs; however, Major Overhauls, defined as the complete teardown and rebuilding of the core compressor block, are considered out of scope of this BOA and must be acquired separately. All repair work shall be executed via individual Task Orders issued against the Basic Ordering Agreement (BOA), or via a formal modification to an existing Task Order, issued exclusively by the Contracting Officer (CO). The Contractor shall adhere strictly to the following workflow: a. Notification and Response Time: Upon equipment malfunction or total system failure, the designated Government Point of Contact (GPOC) / Fire Chief (or authorized representative identified in the Task Order) will notify the Contractor by telephone and email. b. Emergency / Mission-Critical / Flight-Line Impacting Failures: For failures that directly compromise immediate emergency response capabilities, structural firefighting operations, or flightline operations at Edwards AFB (Station 1 or Station 4) or the Plant 42 Fire Station: i. Contractor shall acknowledge receipt of notification within two (2) hours. ii. Contractor certified personnel shall arrive on-site equipped for diagnosis within twenty-four (24) hours of initial notification. c. Routine / Non-Critical Failures: For auxiliary, secondary, or cascade line issues that do not immediately impede primary response readiness: -- 3 of 9 -- P…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 811310