Skip to content

Open for responses

DLA DWCF B1907 Backup Power Generator, Yokosuka, Japan

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
W912HV27Z0002
NAICS
237130
PSC
Y1MZ
Posted
November 12, 2026
Response due
December 11, 2026

What this opportunity is

The U.S. Army Corps of Engineers, Japan District is conducting a market survey for a Design-Bid-Build project to provide a backup power generator in Yokosuka, Japan. This opportunity is specifically aimed at local sources that are licensed to operate in Japan, making it suitable for small businesses based in the region. As this is a Sources Sought notice, it is important for interested firms to respond for market research purposes, rather than to submit bids, as no solicitation has been issued at this time.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

US Army Corps of Engineers Japan District ____________________________________________ FY28 BACKUP POWER GENERATOR, BUILDING 1907 COMMANDER FLEET ACTIVITIES (CFA) YOKOSUKA, JAPAN SPECIFICATIONS INTERMEDIATE SET SUBMITTAL SOLICITATION NO.: TBD CONTRACT AWARD NO.: TBD DATE: SEPTEMBER 2026 Prepared by: Pond-CDM Smith JV JP 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 Pond CDM Smith Project No. 1260134_315106 DRAFT -- 1 of 747 -- This page was intentionally left blank for duplex printing. DRAFT -- 2 of 747 -- Backup Power Generator, Building 1907 27SF0003 Commander Fleet Activities (CFA) Yokosuka, Japan PROJECT TABLE OF CONTENTS DIVISION 01 - GENERAL REQUIREMENTS 01 11 00.00 10 JES 05/26 GENERAL CONTRACT REQUIREMENTS 01 20 00 JES 05/26 PRICE AND PAYMENT PROCEDURES 01 32 01.00 10 08/23; JES 05/26 PROJECT SCHEDULE 01 33 00 08/18, CHG 4: 02/21; SUBMITTAL PROCEDURES 01 35 26 05/24; JES 05/26 GOVERNMENTAL SAFETY REQUIREMENTS 01 42 00 02/19; JES 05/26 SOURCES FOR REFERENCE PUBLICATIONS 01 42 15 JES 05/26 METRIC MEASUREMENTS 01 45 00 08/23, CHG 3: 08/25 QUALITY CONTROL 01 50 00 JES 05/26 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS 01 57 19 01/24; JES 05/26 TEMPORARY ENVIRONMENTAL CONTROLS 01 74 19 01/24; JES 05/26 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT 01 78 00 05/19; JES 05/26 CLOSEOUT SUBMITTALS 01 78 23 JES 05/26 OPERATION AND MAINTENANCE DATA 01 91 00.15 05/23, CHG 3: 08/24 BUILDING COMMISSIONING DIVISION 02 - EXISTING CONDITIONS 02 41 00 08/22 DEMOLITION 02 81 00 01/24; JES 05/26 TRANSPORTATION AND DISPOSAL OF HAZARDOUS MATERIALS 02 82 00 01/24; JES 05/26 ASBESTOS REMEDIATION 02 83 00 01/24; JES 05/26 LEAD REMEDIATION 02 84 16 01/24; JES 05/26 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBS AND MERCURY DIVISION 03 - CONCRETE 03 30 00 02/19; JES 05/26 CAST-IN-PLACE CONCRETE DIVISION 05 - METALS 05 05 20 05/22, CHG 1: 08/24 POST-INSTALLED CONCRETE AND MASONRY ANCHORS 05 05 23.16 08/18; JES 05/26 STRUCTURAL WELDING 05 12 00 08/18; JES 05/26 STRUCTURAL STEEL 05 50 13 05/17; JES 05/26 MISCELLANEOUS METAL FABRICATIONS 05 51 00 02/17, CHG 1: 05/17; METAL STAIRS 05 52 00 02/18; JES 05/26 METAL RAILINGS DIVISION 12 - FURNISHINGS 12 93 00 08/17, CHG 1: 08/18 SITE FURNISHINGS DIVISION 25 - INTEGRATED AUTOMATION 25 05 11.01 08/24 CYBERSECURITY FOR FELECTRICAL-GENERATOR ACILITY-RELATED CONTROL SYSTEMS-LOW IMPACT DIVISION 26 - ELECTRICAL 26 05 13 08/25 MEDIUM-VOLTAGE CABLES 26 05 19.00 10 02/26 INSULATED WIRE AND CABLE TBD DOCUMENT PROJECT Page 1 INTERMEDIATE DESIGN 65% DRAFT -- 3 of 747 -- Backup Power Generator, Building 1907 27SF0003 Commander Fleet Activities (CFA) Yokosuka, Japan 26 05 48 11/23 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT 26 05 73 08/23 POWER SYSTEM STUDIES 26 08 00 11/22 APPARATUS INSPECTION AND TESTING 26 12 19 05/24 PAD-MOUNTED, LIQUID-FILLED, MEDIUM-VOLTAGE TRANSFORMERS 26 13 13 02/26 METAL-CLAD SWITCHGEAR 26 20 00 05/25, CHG 2: 02/26 INTERIOR DISTRIBUTION SYSTEM 26 32 15 02/26 ENGINE-GENERATOR SET STATIONARY 15-2500 KW, WITH AUXILIARIES DIVISION 33 - UTILITIES 33 71 02 02/26, CHG 1: 05/26 UNDERGROUND ELECTRICAL DISTRIBUTION -- End of Project Table of Contents -- TBD DOCUMENT PROJECT Page 2 INTERMEDIATE DESIGN 65% DRAFT -- 4 of 747 -- Backup Power Generator, Building 1907 27SF0003 Commander Fleet Activities (CFA) Yokosuka, Japan SECTION 01 11 00.00 10 GENERAL CONTRACT REQUIREMENTS PART 1 GENERAL 1.1 DEFINITIONS The term "Government" refers to "United States Government" whenever the term "Government" appears in this Contract, unless otherwise indicated within the Contract. 1.2 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE) ASHRAE 189.1 (2017) Standard for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings ASTM INTERNATIONAL (ASTM) ASTM D6245 (2012) Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation ASTM D6345 (2010) Standard Guide for Selection of Methods for Active, Integrative Sampling of Volatile Organic Compounds in Air NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA 10 (2022; ERTA 1 2021) Standard for Portable Fire Extinguishers NFPA 241 (2022) Standard for Safeguarding Construction, Alteration, and Demolition Operations SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION (SMACNA) ANSI/SMACNA 008 (2007) IAQ Guidelines for Occupied Buildings Under Construction, 2nd Edition U.S. ARMY CORPS OF ENGINEERS (USACE) EM 385-1-1 (2024) Safety -- Safety and Occupational Health (SOH) Requirements TBD SECTION 01 11 00.00 10 Page 1 INTERMEDIATE DESIGN 65% DRAFT -- 5 of 747 -- Backup Power Generator, Building 1907 27SF0003 Commander Fleet Activities (CFA) Yokosuka, Japan 1.3 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-01 Preconstruction Submittals Initial Site Conditions Photos Key Personnel Qualifications; G SD-07 Certificates Monthly Progress Photos; SD-11 Closeout Submittals Construction Completion Photos; 1.4 ACCEPTABLE ALTERNATIVE JAPANESE STANDARDS Where indicated in the technical specifications REFERENCES paragraphs, acceptable Japanese standards are listed which are considered acceptable alternatives to the US Standards within the Contract Specifications. Contract specifications authorize the use of specified acceptable alternative Japanese standards. The use of products not meeting the applicable US standards of the Contract or alternative Japanese standards specifically authorized by the Contract is prohibited unless authorized by the Contracting Officer. Japanese …

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 237130