Skip to content

Open for responses

Electric Power Resiliency Building 56

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
SP330027Q0012
NAICS
238210
PSC
Z2GZ
Set-aside
Small Business Set Aside - Total
Posted
November 10, 2026
Response due
December 9, 2026

What this opportunity is

The Department of Defense is seeking a contractor to design and modify the electrical system for Building 56 at the Defense Distribution San Joaquin, California, by installing a 500 KW AC roof-mounted solar photovoltaic system. This opportunity is set aside for small businesses, making it suitable for companies in the electrical contracting sector, particularly those with expertise in solar energy systems. Interested contractors should note that this is a combined synopsis/solicitation, indicating they will need to track the opportunity closely for submission requirements rather than simply bidding.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at theDefense Distribution San Joaquin California.Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaicsystem for building 56. but not limited to:The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed thelisting and qualification tests. All design and installation shall comply with the most recent version of each document.The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor.The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistentwith and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines.There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame sizecircuit breaker spaces are available.

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 238210