Skip to content

Open for responses

Elevator Repair and Maintenance Support Services

DEPT OF DEFENSE

Notice type
Solicitation
Solicitation #
W91RUS-27-R-A002
NAICS
811310
PSC
Z1PZ
Set-aside
Small Business Set Aside - Total
Posted
October 30, 2026
Response due
November 30, 2026
Place of performance
Fort Huachuca, AZ

What this opportunity is

The Department of Defense is seeking elevator repair and maintenance support services under NAICS code 811310, specifically for the inspection, maintenance, and repair of elevator systems at Fort Huachuca, AZ. This opportunity is set aside for small businesses, making it suitable for qualified small contractors in the elevator service industry. Interested vendors should note that this is a solicitation notice, indicating they will need to prepare and submit bids to compete for the contract.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Fort Huachuca, Directorate of Public Works Preventive Maintenance of Electric Elevators Check List Test Performed: Preventive Maintenance (each visit) Building & Unit Information Building Name Owner/Building Management Name Building Address Unit Identification / Unit PIN 8.11.2.1.1 INSIDE CAR INSPECTIONS ASME Section Pass Fail N/A Door reopening device 8.11.2.1.1 Stop switches 8.11.2.1.1 Operating control dev. 8.11.2.1.1 Car floor and landing sill 8.11.2.1.1 Car lighting 8.11.2.1.1 Car emergency signal 8.11.2.1.1 Car door or gate 8.11.2.1.1 Door closing force 8.11.2.1.1 Power closing of doors or gates 8.11.2.1.1 Car vision panels and glass car doors 8.11.2.1.1 Car enclosure 8.11.2.1.1 Emergency exit 8.11.2.1.1 Ventilation 8.11.2.1.1 Signs and operating device symbols 8.11.2.1.1 Rated load, platform area, and data plate 8.11.2.1.1 Standby power operation 8.11.2.1.1 Restricted opening of car or hoistway doors 8.11.2.1.1 Car ride 8.11.2.1.1 Door monitoring system 8.11.2.1.1 Stopping accuracy 8.11.2.1.1 Machinery space/control space 8.11.2.1.1 Working areas in the car - Means to prevent unexpected movement - Unexpected car movement device - Operating instructions for unexpected car movement - Operating instructions for egress and reentry procedures 8.11.2.1.1 Equipment access panel electrical device 8.11.2.1.1 8.11.2.1.2 MACHINE/CONTROL ROOM/SPACE INSPECTIONS ASME Section Pass Fail N/A Equipment exposure to weather 8.11.2.1.2 Means of access 8.11.2.1.2 Headroom 8.11.2.1.2 Means necessary for tests 8.11.2.1.2 Inspection and test panel 8.11.2.1.2 Lighting and receptacles 8.11.2.1.2 Enclosure of machine room/spaces, control room/spaces 8.11.2.1.2 Housekeeping 8.11.2.1.2 Ventilation 8.11.2.1.2 Fire extinguisher 8.11.2.1.2 Pipes, wiring, and ducts 8.11.2.1.2 Guarding of equipment 8.11.2.1.2 Numbering of elevators, machines, and disconnect switches 8.11.2.1.2 Maintenance path and maintenance clearance 8.11.2.1.2 Stop switch 8.11.2.1.2 Disconnecting means and control 8.11.2.1.2 Controller wiring, fused, grounding 8.11.2.1.2 Static control 8.11.2.1.2 Machinery supports and fastenings 8.11.2.1.2 Drive machine brake 8.11.2.1.2 Traction drive machines 8.11.2.1.2 Gears bearings and flexible connections 8.11.2.1.2 Winding drum machine 8.11.2.1.2 Belt-or chain drive machine 8.11.2.1.2 Motor generator 8.11.2.1.2 Absorption of regenerated power 8.11.2.1.2 Traction sheaves 8.11.2.1.2 Secondary and deflector sheaves 8.11.2.1.2 Rope fastenings 8.11.2.1.2 Terminal stopping devices 8.11.2.1.2 Operating devices 8.11.2.1.2 Governor over speed switch and seal 8.11.2.1.2 Car and counterweight safeties 8.11.2.1.2 Code data plate 8.11.2.1.2 Emergency brake 8.11.2.1.2 AC drives form a DC source 8.11.2.1.2 Slack rope device 8.11.2.1.2 Wiring diagrams 8.11.2.1.2 8.11.2.1.3 TOP-OF-CAR INSPECTIONS ASME Section Pass Fail N/A Top-of-car stop switch 8.11.2.1.3 Car top light and outlet 8.11.2.1.3 Top-of-car operating device and platforms 8.11.2.1.3 Top counterweight clearance 8.11.2.1.3 Car, overhead, and deflector 8.11.2.1.3 Normal terminal stopping devices 8.11.2.1.3 Final Terminal Stopping Devices 8.11.2.1.3 Broken Rope, Chain, or Tape Switch 8.11.2.1.3 Car Leveling Devices 8.11.2.1.3 Crosshead Data Plate 8.11.2.1.3 Top Emergency Exit 8.11.2.1.3 Counterweight and Counterweight Buffer 8.11.2.1.3 Counterweight Safeties 8.11.2.1.3 Floor, and Emergency Identification Numbering 8.11.2.1.3 Hoistway Construction 8.11.2.1.3 Hoistway Smoke Control 8.11.2.1.3 Pipes, Wiring, and Ducts 8.11.2.1.3 Windows, Projections, Recesses, and setbacks Setbacks 8.11.2.1.3 Hoistway Clearances 8.11.2.1.3 Multiple Hoistways 8.11.2.1.3 Traveling Cables and Junction Boxes 8.11.2.1.3 Door and Gate Equipment 8.11.2.1.3 Car Frame and Stiles 8.11.2.1.3 Guide Rails Fastening and Equipment 8.11.2.1.3 Governor Rope. Governor ropes should be inspected and replaced as outlined for traction elevator suspension and compensating ropes 8.11.2.1.3 Governor Releasing Carrier 8.11.2.1.3 Wire Rope Fastening and Hitch Plate 8.11.2.1.3 Suspension & Compensating Rose - Wire suspension and compensating ropes shall be replaced (a) if the broken wires are equally distributed per rope lay in the worst section of the rope exceeds the value shown in column A of table 8.11.2.1.3 (b) if the distribution of broken wires is unequal and broken wires predominate in one or two stands, when the number of broken wires per rope lay in the worst section of the rope exceeds the values shown in column B of Table 8.11.2.3 (cc)(1); or (c) if four or five wires, side by side, are broken across the crown of any strand, when the number of broken wires per rope lay in the worst section of rope exceeds values shown in column C of Table 8.11.2.1.3 (cc)(1); or (d) if in the judgment of the inspector, any unfavorable condition, such as fretting corrosion (red dust or rouge), excessive wear of individual wires in the strands, unequal tension, poor sheave grooves, etc., exists, the criteria for broken wires will be reduced by 50% of the values indicated in Table 8.11.2.1.3(cc) (1) for any of the three conditions described above; or (e) if there is more than one valley break per rope lay. - On winding drum m…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 811310