Skip to content

Open for responses

JB MDL, NJ | Oil Water Separator Services

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
FA4484XXC0001
NAICS
562998
PSC
S222
Set-aside
Small Business Set Aside - Total
Posted
November 12, 2026
Response due
November 27, 2026
Place of performance
0, NJ

What this opportunity is

The Department of Defense is seeking small businesses to provide preventative maintenance and repair services for oil water separator systems at Joint Base McGuire-Dix-Lakehurst, NJ. This opportunity is set aside for total small business participation, making it suitable for qualified small contractors with specific certifications and equipment ownership. Interested firms should note that this is a sources sought notice, indicating a focus on gathering information rather than immediate bidding, which may require tracking for future solicitation announcements.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

PERFORMANCE WORK STATEMENT FOR THE PREVENTATIVE MAINTENANCE / REPAIR OF OIL WATER SEPARATOR SYSTEMS AT JOINT BASE MCGUIRE-DIX-LAKEHURST Joint Base McGuire-Dix-Lakehurst 5 November 2026 -- 1 of 14 -- PERFORMANCE WORK STATEMENT FOR PREVENTATIVE MAINTENANCE / REPAIR OF OIL WATER SEPARATOR SYSTEMS AT JOINT BASE MCGUIRE-DIX-LAKEHURST 1. DESCRIPTION OF SERVICES. The contractor shall provide all management, tools, supplies, equipment, and labor required to clean, inspect, and repair Oil Water Separator (OWS) systems at Joint Base McGuire-Dix-Lakehurst. 1.0.1 To perform this mission, the Prime Contractor must directly hold, maintain, and provide proof of the following specific equipment ownership/lease agreements and active personnel certifications in the Prime Contractor's name at the time of proposal submission and throughout the life of the contract: Personal Certifications • NJDEP A-901 Hauler License (N.J.S.A. 13:1E-126) • 40-Hour HAZWOPER (OSHA 1910.120) • Confined Space Entry (OSHA 1910.146) • Certified OWS Alarm Technician License Mission Equipment • DOT-certified vacuum tankers • Explosion-proof pumps • Confined-space ventilation systems • Certified waste storage tanks 1.1. BASIC SERVICES. The contractor shall perform preventative maintenance and repairs of OWS systems, which consists of inspecting, testing alarms and sensors, emptying, cleaning, recharging, and disposing of each system’s tanks, collection entry points, piping, vaults, and alarm systems. The contractor shall dispose of the OWS systems’ contents at an appropriate disposal site or treatment facility that complies with the Resource Conservation and Recovery Act (RCRA), as well as all local, State, and Federal laws and regulations regarding waste disposal. For operational guidance, the contractor shall strictly adhere to: Air Force Occupational Safety, Fire, and Health Standards (DAFMAN 91-203, 25 March 2022); DODI 4715.6 Environmental Compliance (4 May 2015); Department of the Air Force Manual (DAFMAN) 32-1067 Water and Fuel Systems (4 August 2020); AFI 32-7001 Environmental Management (23 August 2019); Department of the Air Force Instruction (DAFI) 23-201 Fuels Management (23 August 2023); 33 USC 1251 et seq., Clean Water Act; and NJAC 7:14A New Jersey Pollution Discharge Elimination System. Specific workload estimates are detailed in Appendix A. 1.2. CLEANING AND INSPECTION. Following schedule coordination and cleaning procedure review with the Contracting Officer Representative (COR), the contractor shall isolate the oil-water separator (OWS) vaults and pump out all contents including free-floating oil, contaminated wastewater, sludge, and debris using specialized vacuum equipment, immediately halting operations and notifying the COR if suspected hazardous materials are identified. Extracted waste must be transported under a State-approved EPA waste manifest to a licensed Treatment, Storage, and Disposal Facility (TSDF) under CLIN X004. The contractor shall pressure wash or steam clean all collection entry points, interior chamber walls, tanks, piping, filters, screens, and media vaults -- 2 of 14 -- (disassembling as needed), clearing and water-flow testing lines to verify the system is free of obstructions. Upon COR approval of the cleaning, the contractor shall conduct a comprehensive multi-point inspection adhering to manufacturer and industry standards including visual assessments, nondestructive structural testing, and functional testing of floor grates, piping, valves, catch basins, baffles, coalescing plates, protective coatings, and liquid-level alarms and complete necessary repairs in accordance with paragraph 1.4. Prior to returning the unit to service, the contractor shall recharge the system with fresh potable water using a reduced pressure zone (RPZ) backflow preventer to the depth required to activate the hydraulic separation barrier, submitting a comprehensive written inspection report to the COR within five (5) business days. 1.3. ALARM SYSTEMS. The contractor shall inspect and test all control monitoring systems to include floats, wiring, lights, strobes, etc., to ensure all components of the alarm systems are in good working condition. 1.4. REPAIRS. The contractor shall repair all mechanical, electrical, control, and safety deficiencies because of the preventative maintenance and service calls. The contractor shall repair the OWS equipment at the contractor’s expense if the material cost is less than $100.00 or less per system. If the repair work is between $100.00 and $2,500.00 in total costs, the contractor shall provide a written repair cost estimate to the COR within two (2) business days of finding the deficiency requesting authorization to proceed. The written repair cost estimate shall include, at a minimum, the following: the estimated cost of material, the labor hours needed to complete repairs, and the projected time the equipment will be out of service. The contractor shall be financially compensated for material and labor costs only if COR authorization is granted. At no time shall work more than $100.00 be completed without COR approval. If the work exceeds $2,500.00 in total costs, the contractor shall provide a written repair cost estimate directly to the Contracting Officer (CO) only (not to the COR) within two (2) business days of finding the deficiency. The written repair cost estimate shall include, at a minimum, the following: the estimated cost of the material, the labor hours needed to complete the repairs, and the projected time the equipment will be out of service. The contractor shall be financially compensated for the material and labor costs only if CO authorization is granted. At no time shall work more than $2,500.00 be completed without CO approval. There’s no maximum financial threshold for major repairs under this contract. The contractor shall ensure all major repair work commences within three (3) days of COR or CO approval. The contracto…

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Open opportunities in NAICS 562998